Regional pressure-flow relationships within the right coronary artery (RCA) circulation of swine were determined. Enflurane-anaesthetized swine (n = 7) were studied during step-wise reductions of RCA perfusion pressure using an extracorporeal circuit. Regional blood flow was measured using microspheres and contractile function of the right ventricle was measured using sonomicrometry. The RCA perfusion territory was divided into its anatomic components: right ventricular free wall (RV), interventricular septum (with further division in transmural thirds; SEP-LV, SEP-MID and SEP-RV) and right atrium (RA). Pressure-flow relations were constructed for each region and autoregulatory capacity assessed through calculation of an autoregulatory index (AI, closed-loop gain). The pressure-flow relationship for the entire RCA exhibited autoregulation down to a pressure of 40 mmHg. The SEP-LV exhibited a similar relationship with loss of autoregulation at approximately 40 mmHg. The pressure-flow relationship of the RV, however, showed autoregulation to a pressure of 30 mmHg with a decrease of blood flow only at a pressure of 20 mmHg. Little autoregulation was observed in the RA. Autoregulatory gain assessed by AI was similar in RV, SEP-LV and SEP-RV as pressure was reduced from 90 to 55 mmHg (RV = 0.54 +/- 0.41; SEP-LV = 0.58 +/- 0.36; SEP-RV = 0.83 +/- 0.36). With further reductions of pressure, AI was highest in the RV, followed by the SEP-RV and then SEP-LV.(ABSTRACT TRUNCATED AT 250 WORDS)
测定了猪右冠状动脉(RCA)循环内的区域压力 - 血流关系。使用体外循环对七氟醚麻醉的猪(n = 7)在逐步降低RCA灌注压力的过程中进行研究。使用微球测量区域血流量,并使用超声心动图测量右心室的收缩功能。RCA灌注区域被分为其解剖成分:右心室游离壁(RV)、室间隔(进一步分为透壁的三层;SEP - LV、SEP - MID和SEP - RV)以及右心房(RA)。为每个区域构建压力 - 血流关系,并通过计算自动调节指数(AI,闭环增益)评估自动调节能力。整个RCA的压力 - 血流关系显示在压力降至40 mmHg时仍具有自动调节能力。SEP - LV表现出类似的关系,在约40 mmHg时自动调节能力丧失。然而,RV的压力 - 血流关系显示在压力降至30 mmHg时具有自动调节能力,仅在压力为20 mmHg时血流量减少。在RA中未观察到明显的自动调节。当压力从90 mmHg降至55 mmHg时,通过AI评估的自动调节增益在RV、SEP - LV和SEP - RV中相似(RV = 0.54 +/- 0.41;SEP - LV = 0.58 +/- 0.36;SEP - RV = 0.83 +/- 0.36)。随着压力进一步降低,AI在RV中最高,其次是SEP - RV,然后是SEP - LV。(摘要截断于250字)