Suppr超能文献

用于高通量测定盐酸四咪唑的电位传感器。

Potentiometric sensor for the high throughput determination of tetramisole hydrochloride.

作者信息

Gupta Vinod Kumar, Singh Ashok Kumar, Gupta Barkha

机构信息

Department of Chemistry, Indian Institute of Technology, Roorkee, India.

出版信息

Comb Chem High Throughput Screen. 2007 Aug;10(7):583-94. doi: 10.2174/138620707782152371.

Abstract

The electrochemical response characteristics of poly(vinyl)chloride (PVC) based membrane sensors for determination of tetramisole hydrochloride (TmCl) is described. The membranes of these electrodes consist of tetramisole-tetraphenyl borate (Tm-TPB), chlorophenyl borate (Tm-ClPB), and phosphotungstate (Tm(3)-PT) ion associations dispersed in a PVC matrix with dibutylpthalate as a plasticizer. The electrodes were fully characterized in terms of composition, life span, usable pH range, and working concentration range and ionic strength. The electrodes showed Nernstian response over the concentration ranges of 7.4 x 10(-7) to 1.0 x 10(-2) M, 1.7 x 10(-6) to 1.0 x 10(-2) M, and 5.6 x 10(-6) to 1.0 x 10(-2) M TmCl, respectively, and were applied to the potentiometric determination of tetramisole ion in pure solutions and pharmaceutical preparations. The potentiometric determination was also used in the determination of tetramisole in pharmaceutical preparations in four batches of different expiration dates. The electrodes exhibited good selectivity for TmCl with respect to a large number of excipients such as inorganic cations, organic cations, amino acids, and sugars. The solubility product of the ion-pair and the formation constant of the precipitation reaction leading to the ion-pair formation were determined conductometrically. The new potentiometric method offers the advantages of high-throughput determination, simplicity, accuracy, automation feasibility, and applicability to turbid and colored sample solutions.

摘要

描述了用于测定盐酸四咪唑(TmCl)的聚氯乙烯(PVC)基膜传感器的电化学响应特性。这些电极的膜由四咪唑-四苯基硼酸盐(Tm-TPB)、氯苯基硼酸盐(Tm-ClPB)和磷钨酸盐(Tm(3)-PT)离子缔合物分散在以邻苯二甲酸二丁酯为增塑剂的PVC基质中组成。对电极在组成、寿命、可用pH范围、工作浓度范围和离子强度方面进行了全面表征。电极分别在7.4×10(-7)至1.0×10(-2) M、1.7×10(-6)至1.0×10(-2) M和5.6×10(-6)至1.0×10(-2) M的TmCl浓度范围内呈现能斯特响应,并应用于纯溶液和药物制剂中四咪唑离子的电位测定。电位测定还用于测定四批不同有效期药物制剂中的四咪唑。相对于大量赋形剂,如无机阳离子、有机阳离子、氨基酸和糖类,电极对TmCl表现出良好的选择性。通过电导法测定了离子对的溶度积和导致离子对形成的沉淀反应的形成常数。这种新的电位测定方法具有高通量测定、简单、准确、自动化可行性以及适用于浑浊和有色样品溶液等优点。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验