Suppr超能文献

表现为黄斑旁高密度眼底自发荧光环异常的视网膜营养不良患者的功能特征;综述与更新

Functional characteristics of patients with retinal dystrophy that manifest abnormal parafoveal annuli of high density fundus autofluorescence; a review and update.

作者信息

Robson Anthony G, Michaelides Michel, Saihan Zubin, Bird Alan C, Webster Andrew R, Moore Anthony T, Fitzke Fred W, Holder Graham E

机构信息

Department of Electrophysiology, Moorfields Eye Hospital, 162 City Road, London EC1 2PD, UK.

出版信息

Doc Ophthalmol. 2008 Mar;116(2):79-89. doi: 10.1007/s10633-007-9087-4. Epub 2007 Nov 6.

Abstract

PURPOSE

To examine the presence and functional significance of annular fundus autofluorescence abnormalities in patients with different retinal dystrophies.

METHODS

Eighty one patients were ascertained who had a parafoveal ring of high density on fundus autofluorescence imaging. Sixty two had had a clinical diagnosis of retinitis pigmentosa (RP) or Usher syndrome with normal visual acuity. Others included a case of Leber congenital amaurosis and genetically confirmed cases of cone or cone-rod dystrophy (GUCA1A, RPGR, RIMS1), "cone dystrophy with supernormal rod ERG" (KCNV2) and X-linked retinoschisis (RS1). International-standard full-field and pattern electroretinography (ERG; PERG) were performed. Some patients with rod-cone or cone-rod dystrophy underwent multifocal ERG (mfERG) testing and photopic and scotopic fine matrix mapping (FMM).

RESULTS

In patients with RP, the radius of the parafoveal ring of high density correlated with PERG P50 (R = 0.83, P < 0.0005, N = 62) and encircled areas of preserved photopic function. In the other patients, AF rings either resembled those seen in RP or encircled an area of central atrophy. Ring radius was inversely related to the PERG P50 component in 4 of 18 cases with a detectable response. FMM showed that arcs of high density were associated with a gradient of sensitivity change.

CONCLUSIONS

Parafoveal rings of high density autofluorescence are a non-specific manifestation of retinal dysfunction that can occur in different retinal dystrophies. Electrophysiology remains essential for accurate diagnosis. The high correlation of autofluorescence with PERG, mfERG and FMM demonstrates that AF abnormalities have functional significance and may help identify suitable patients and retinal areas amenable to future therapeutic intervention.

摘要

目的

研究不同视网膜营养不良患者中环形眼底自发荧光异常的存在情况及其功能意义。

方法

确定81例在眼底自发荧光成像上有黄斑旁高密度环的患者。其中62例临床诊断为色素性视网膜炎(RP)或视力正常的Usher综合征。其他患者包括1例Leber先天性黑矇以及基因确诊的视锥或视锥 - 视杆营养不良(GUCA1A、RPGR、RIMS1)、“超常视杆ERG的视锥营养不良”(KCNV2)和X连锁视网膜劈裂症(RS1)患者。进行了国际标准的全视野和图形视网膜电图(ERG;PERG)检查。一些视杆 - 视锥或视锥 - 视杆营养不良患者接受了多焦ERG(mfERG)测试以及明视和暗视精细矩阵映射(FMM)。

结果

在RP患者中,黄斑旁高密度环的半径与PERG的P50相关(R = 0.83,P < 0.0005,N = 62),并且环绕着保留明视功能的区域。在其他患者中,自发荧光环要么类似于RP患者所见的环,要么环绕着中央萎缩区域。在18例有可检测反应的病例中,有4例环半径与PERG的P50成分呈负相关。FMM显示高密度弧与敏感度变化梯度相关。

结论

黄斑旁高密度自发荧光环是视网膜功能障碍的非特异性表现,可发生于不同的视网膜营养不良。电生理学对于准确诊断仍然至关重要。自发荧光与PERG、mfERG和FMM的高度相关性表明,自发荧光异常具有功能意义,可能有助于识别适合未来治疗干预的患者和视网膜区域。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/395c/2244701/1d1884d8adfa/10633_2007_9087_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验