Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

作者信息

Valentin J

出版信息

Ann ICRP. 2007;37(1):1-79, iii. doi: 10.1016/j.icrp.2007.09.001.

Abstract

Computed tomography (CT) technology has changed considerably in recent years with the introduction of increasing numbers of multiple detector arrays. There are several parameters specific to multi-detector computed tomography (MDCT) scanners that increase or decrease patient dose systematically compared to older single detector computed tomography (SDCT) scanners. This document briefly reviews the MDCT technology, radiation dose in MDCT, including differences from SDCT and factors that affect dose, radiation risks, and the responsibilities for patient dose management. The document recommends that users need to understand the relationship between patient dose and image quality and be aware that image quality in CT is often higher than that necessary for diagnostic confidence. Automatic exposure control (AEC) does not totally free the operator from selection of scan parameters, and awareness of individual systems is important. Scanning protocols cannot simply be transferred between scanners from different manufacturers and should be determined for each MDCT. If the image quality is appropriately specified by the user, and suited to the clinical task, there will be a reduction in patient dose for most patients. Understanding of some parameters is not intuitive and the selection of image quality parameter values in AEC systems is not straightforward. Examples of some clinical situation shave been included to demonstrate dose management, e.g. CT examinations of the chest, the heart for coronary calcium quantification and non-invasive coronary angiography, colonography, the urinary tract, children, pregnant patients, trauma cases, and CT guided interventions. CT is increasingly being used to replace conventional x-ray studies and it is important that patient dose is given careful consideration, particularly with repeated or multiple examinations.

摘要

近年来,随着多探测器阵列数量的不断增加,计算机断层扫描(CT)技术发生了很大变化。与老式单探测器计算机断层扫描(SDCT)扫描仪相比,多探测器计算机断层扫描(MDCT)扫描仪有几个特定参数会系统地增加或减少患者剂量。本文简要回顾了MDCT技术、MDCT中的辐射剂量,包括与SDCT的差异以及影响剂量的因素、辐射风险,以及患者剂量管理的职责。本文建议用户需要了解患者剂量与图像质量之间的关系,并意识到CT图像质量往往高于诊断置信度所需的水平。自动曝光控制(AEC)并不能完全使操作员免于选择扫描参数,了解各个系统很重要。扫描协议不能简单地在不同制造商的扫描仪之间转移,每种MDCT都应确定相应的扫描协议。如果用户适当地指定图像质量并使其适合临床任务,大多数患者的剂量将会降低。对某些参数的理解并不直观,AEC系统中图像质量参数值的选择也不简单。文中包含了一些临床情况的示例,以展示剂量管理,例如胸部CT检查、用于冠状动脉钙化定量和无创冠状动脉造影的心脏CT检查、结肠成像、泌尿系统CT检查、儿童CT检查、孕妇CT检查、创伤病例CT检查以及CT引导介入检查。CT越来越多地被用于取代传统的X线检查,认真考虑患者剂量非常重要,尤其是在重复或多次检查时。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验