Radiation Doses in Routine CT Examinations for Adult Patients in Saudi Arabia: A Systematic Review.

作者信息

Alenazi Khaled

机构信息

Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, Riyadh, SAU.

出版信息

Cureus. 2024 Jul 16;16(7):e64646. doi: 10.7759/cureus.64646. eCollection 2024 Jul.

Abstract

Computed tomography (CT) is an important imaging technique that produces detailed cross-sectional images for diagnosing medical conditions. However, the associated radiation exposure raises concerns. Establishing diagnostic reference levels (DRLs) helps identify unusual radiation doses and optimize exposure while maintaining diagnostic image quality. The purpose of this systematic review is to review the radiation doses received by adult patients in the head, chest, abdomen, pelvis, abdomen-pelvis (AP), and combined chest, abdomen, and pelvis (CAP) CT scans in Saudi Arabia. A search was conducted in several databases including PubMed and Google Scholar to identify studies that have established DRLs or determined radiation dose for adult CT examinations. Only studies that specifically assessed DRLs in actual adult patients were considered for inclusion. Out of a total of 31 articles that were identified as eligible, 13 were included after a thorough screening process. The values of CTDI, DLP, and effective doses were determined. The review discovered that CTDI and DLP were the most frequently used dosimetric quantities. The mean values in terms of CTDI for head, chest, abdomen, pelvis, AP, and CAP ranged from 40.67 to 61.80 mGy, 5.80 to 14.90 mGy, 8.60 to 16.15 mGy, 10.80 to 17.35 mGy, 14.10 to 16.84 mGy, and 12.00 to 22.94 mGy, respectively. The mean values in terms of DLP for head, chest, abdomen, pelvis, AP, and CAP ranged from 757 to 1212 mGy.cm, 243 to 657 mGy.cm, 369.5 to 549 mGy.cm, 379.6 to 593 mGy.cm, 658 to 940.43 mGy.cm, and 740 to 1493.8 mGy.cm, respectively. There is a fluctuation in radiation dose among CT centers, highlighting a need to provide proper education and training to radiographers. It is recommended to establish a universally accepted standardized protocol based on weight, equivalent diameter, or cross-sectional area for accurate comparisons with national and international DRLs.

摘要

计算机断层扫描(CT)是一种重要的成像技术,可生成用于诊断疾病的详细断层图像。然而,相关的辐射暴露引发了人们的担忧。建立诊断参考水平(DRL)有助于识别异常的辐射剂量,并在保持诊断图像质量的同时优化辐射暴露。本系统评价的目的是回顾沙特阿拉伯成年患者在头部、胸部、腹部、骨盆、腹部-骨盆(AP)以及胸部、腹部和骨盆联合扫描(CAP)CT检查中所接受的辐射剂量。在包括PubMed和谷歌学术在内的多个数据库中进行了检索,以识别已建立DRL或确定成年CT检查辐射剂量的研究。仅纳入专门评估实际成年患者DRL的研究。在总共识别出的31篇符合条件的文章中,经过全面筛选后纳入了13篇。确定了CTDI、DLP和有效剂量的值。该评价发现,CTDI和DLP是最常用的剂量学量。头部、胸部、腹部、骨盆、AP和CAP的CTDI平均值分别为40.67至61.80 mGy、5.80至14.90 mGy、8.60至16.15 mGy、10.80至17.35 mGy、14.10至16.84 mGy以及12.00至22.94 mGy。头部、胸部、腹部、骨盆、AP和CAP的DLP平均值分别为757至1212 mGy.cm、243至657 mGy.cm、3

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c9cf/11325851/43d77048950f/cureus-0016-00000064646-i01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验