Inaccuracies of oximetry in identifying the location of intracardiac left-to-right shunts in adults.

作者信息

Ahmed Salim, Lange Richard A, Hillis L David

机构信息

Departments of Internal Medicine, Cardiovascular Divisions, University of Texas Southwestern Medical Center, Dallas, Texas, USA.

出版信息

Am J Cardiol. 2008 Jan 15;101(2):245-7. doi: 10.1016/j.amjcard.2007.07.071.

DOI:10.1016/j.amjcard.2007.07.071
PMID:18178415
Abstract

Although oximetric analysis of blood from the right heart chambers is the most commonly used method for assessing the presence of intracardiac left-to-right shunting, it sometimes provides misleading information because a patient with a left-to-right shunt in only 1 location sometimes manifests a significant oxygen step-up (1) in >1 chamber or (2) in a chamber other than that in which the shunt is actually located. This study was performed (1) to assess the frequency with which oximetric data provide such misleading results and (2) to determine which variables (if any) may contribute to the occurrence of such erroneous oximetric results. Accordingly, we analyzed oximetric data from 168 patients (61 men, 107 women, 14 to 76 years of age) with a proved left-to-right shunt at only 1 site and oximetric evidence of significant oxygen step-up. Using the criteria of Dexter et al (J Clin Invest 1947;26:554-560), Antman et al (Am J Cardiol 1980;46:265-271), or Pirwitz et al (Am Heart J 1997;133:413-417) for a significant oxygen step-up, 34%, 42%, and 35% of subjects, respectively, manifested a significant step-up in >1 chamber or a step-up only in an incorrect chamber. Compared with those with a step-up in the correct chamber only, those with a step-up in >1 chamber had larger Qp/Qs ratios (mean +/- SD, 2.7 +/- 1.2 vs 3.5 +/- 1.8, respectively, p <0.001), whereas subjects with a step-up only in an incorrect chamber had smaller Qp/Qs ratios than those with a step-up in the correct chamber (2.2 +/- 0.9 vs 2.8 +/- 1.3, respectively, p <0.001). In conclusion, in adult subjects with left-to-right intracardiac shunting in only 1 location, carefully obtained oximetric data often provide erroneous information.

摘要

相似文献

1
Inaccuracies of oximetry in identifying the location of intracardiac left-to-right shunts in adults.
Am J Cardiol. 2008 Jan 15;101(2):245-7. doi: 10.1016/j.amjcard.2007.07.071.
2
Measurements of left-to-right intracardiac shunting in adults: oximetric versus indicator dilution techniques.
Cathet Cardiovasc Diagn. 1985;11(5):467-72. doi: 10.1002/ccd.1810110505.
3
A critical reappraisal of the oximetric assessment of intracardiac left-to-right shunting in adults.对成人心脏内左向右分流的血氧测定评估的批判性重新评估。
Am Heart J. 1997 Apr;133(4):413-7. doi: 10.1016/s0002-8703(97)70182-0.
4
Assessment of left-to-right intracardiac shunting by velocity-encoded, phase-difference magnetic resonance imaging. A comparison with oximetric and indicator dilution techniques.通过速度编码、相位差磁共振成像评估心内左向右分流。与血氧测定法和指示剂稀释技术的比较。
Circulation. 1995 Jun 15;91(12):2955-60. doi: 10.1161/01.cir.91.12.2955.
5
Variability of right-sided cardiac oxygen saturations in adults with and without left-to-right intracardiac shunting.有和没有心内左向右分流的成人右侧心脏血氧饱和度的变异性。
Am J Cardiol. 1986 Jul 1;58(1):129-32. doi: 10.1016/0002-9149(86)90255-9.
6
Role of oximeter error in the diagnosis of shunts.血氧饱和度仪误差在分流诊断中的作用。
Cathet Cardiovasc Diagn. 1996 Apr;37(4):435-46. doi: 10.1002/(SICI)1097-0304(199604)37:4<435::AID-CCD14>3.0.CO;2-E.
7
Assessment of the sensitivity of hydrogen inhalation in the detection of left-to-right shunting.氢气吸入在检测左向右分流中的敏感性评估。
Cathet Cardiovasc Diagn. 1990 Jun;20(2):94-8. doi: 10.1002/ccd.1810200206.
8
Effect of oximetry error on the diagnostic value of the Qp/Qs ratio.血氧饱和度测量误差对Qp/Qs比值诊断价值的影响。
Int J Cardiol. 1997 Oct 10;61(3):247-59. doi: 10.1016/s0167-5273(97)00167-8.
9
Detection of intracardiac left-to-right shunting in adults: a prospective analysis of the variability of the standard indocyanine green technique in patients without shunting.
Am J Cardiol. 1987 Aug 1;60(4):355-7. doi: 10.1016/0002-9149(87)90242-6.
10
Bedside nuclear probe for detection and quantification of left to right intracardiac shunts.用于检测和定量心内左向右分流的床边核探头。
Br Heart J. 1988 Apr;59(4):463-7. doi: 10.1136/hrt.59.4.463.