Büchner Andreas, Nogueira Waldo, Edler Bernd, Battmer Rolf-Dieter, Lenarz Thomas
Department of Otolaryngology, Medical University of Hannover, Hannover, Germany.
Otol Neurotol. 2008 Feb;29(2):189-92. doi: 10.1097/mao.0b013e318162512c.
In normal-hearing listeners acoustic masking occurs depending on frequency, amplitude, and energy of specific signals. If the selection of stimulated channels in cochlear implant systems was based on psychoacoustic masking models, the bandwidth of the electrode/nerve interface could be used more effectively by concentrating on relevant signal components and neglecting those that are usually not perceived by normal hearing listeners. Subsequently, a new strategy called PACE (Psychoacoustic Advanced Combination Encoder) has been developed which uses a psychoacoustic model for the channel selection instead of the simple maxima selection algorithm of the ACE strategy.
Only subjects having at least 2 years experience with the ACE strategy were included. A counterbalanced cross-over design was used to compare the new speech coding strategy with the ACE strategy.
The investigation was a prospective, within-subject, repeated-measures experiment.
The study group consisted of 10 postlingually deafened adult subjects.
The following programs were evaluated: (1) ACE with 8 maxima selected; (2) PACE with 8 channels selected; and (3) PACE with 4 channels selected.
Speech perception tests in quiet and noise, Quality Assessment Questionnaire.
Results indicate a trend towards better performance with PACE. Scores in the Freiburg monosyllabic word test increased by 8% while the SNR50 in the Oldenburger sentence test improved significantly by 1.3 dB.
The use of psychoacoustic masking models in speech coding strategies has the potential to improve speech perception performance in cochlear implant subjects.
在听力正常的听者中,声学掩蔽取决于特定信号的频率、幅度和能量。如果人工耳蜗系统中受刺激通道的选择基于心理声学掩蔽模型,那么通过专注于相关信号成分并忽略那些正常听力听者通常无法感知的成分,电极/神经接口的带宽可以得到更有效的利用。随后,一种名为PACE(心理声学高级组合编码器)的新策略被开发出来,该策略使用心理声学模型进行通道选择,而不是ACE策略中简单的最大值选择算法。
仅纳入至少有2年ACE策略使用经验的受试者。采用平衡交叉设计将新的语音编码策略与ACE策略进行比较。
该研究是一项前瞻性的、受试者内重复测量实验。
研究组由10名语后聋成年受试者组成。
评估以下程序:(1)选择8个最大值的ACE;(2)选择8个通道的PACE;(3)选择4个通道的PACE。
安静和噪声环境下的语音感知测试、质量评估问卷。
结果表明PACE有表现更好的趋势。在弗莱堡单音节词测试中的得分提高了8%,而在奥尔登堡句子测试中的SNR50显著提高了1.3 dB。