An immunochromatographic assay (Campy-ICA) using a newly generated single monoclonal antibody against a 15-kDa cell surface protein of Campylobacter jejuni was developed. When cell suspensions of 86 C. jejuni strains and 27 Campylobacter coli strains were treated with a commercially available bacterial protein extraction reagent and the resulting extracts were tested with the Campy-ICA, they all yielded positive results. The minimum detectable limits for the C. jejuni strains ranged from 1.8 x 10(4) to 8.2 x 10(5) CFU/ml of cell suspension, and those for the C. coli strains ranged from 1.4 x 10(5) to 4.6 x 10(6) CFU/ml of cell suspension. All 26 non-Campylobacter species tested yielded negative results with the Campy-ICA. To evaluate the ability of the Campy-ICA to detect C. jejuni and C. coli in human stool specimens, suspensions of 222 stool specimens from patients with acute gastroenteritis were treated with the bacterial protein extraction reagent, and the resulting extracts were tested with the Campy-ICA. The Campy-ICA results showed a sensitivity of 84.8% (28 of 33 specimens) and a specificity of 100% (189 of 189 specimens) compared to the results of isolation of C. jejuni and C. coli from the stool specimens by a bacterial culture test. The Campy-ICA was simple to perform and was able to detect Campylobacter antigen in a fecal extract within 15 min. These results suggest that Campy-ICA testing of fecal extracts may be useful as a simple and rapid adjunct to stool culture for detecting C. jejuni and C. coli in human stool specimens.
研发了一种免疫层析检测法(弯曲菌免疫层析检测法,Campy-ICA),该方法使用了新产生的针对空肠弯曲菌15 kDa细胞表面蛋白的单克隆抗体。用市售细菌蛋白提取试剂处理86株空肠弯曲菌菌株和27株结肠弯曲菌菌株的细胞悬液,并用Campy-ICA检测所得提取物,结果均为阳性。空肠弯曲菌菌株的最低检测限为每毫升细胞悬液1.8×10⁴至8.2×10⁵CFU,结肠弯曲菌菌株的最低检测限为每毫升细胞悬液1.4×10⁵至4.6×10⁶CFU。所检测的26种非弯曲菌属物种用Campy-ICA检测均为阴性结果。为评估Campy-ICA检测人粪便标本中空肠弯曲菌和结肠弯曲菌的能力,用细菌蛋白提取试剂处理222份急性肠胃炎患者粪便标本的悬液,并用Campy-ICA检测所得提取物。与通过细菌培养试验从粪便标本中分离空肠弯曲菌和结肠弯曲菌的结果相比,Campy-ICA结果显示敏感性为84.8%(33份标本中的28份),特异性为100%(189份标本中的189份)。Campy-ICA操作简单,能够在15分钟内检测粪便提取物中的弯曲菌抗原。这些结果表明,对粪便提取物进行Campy-ICA检测作为一种简单快速的辅助方法,可能有助于在人粪便标本中检测空肠弯曲菌和结肠弯曲菌。