使用JMA电子记录系统和前伸蜡记录来设置牙合架对髁突水平倾斜度的比较临床研究。

Comparative clinical investigation of horizontal condylar inclination using the JMA electronic recording system and a protrusive wax record for setting articulators.

作者信息

Ratzmann A, Mundt T, Schwahn C, Langforth G, Hutzen D, Gedrange T, Kordass B

机构信息

Poliklinik für Kieferorthopädie, Ernst- Moritz-Arndt-Universität Greifswald, Germany.

出版信息

Int J Comput Dent. 2007 Jul;10(3):265-84.

Abstract

PURPOSE

The rationale for recording protrusive mandibular movement is to accurately adjust an articulator. Techniques to record condylar inclination include extraoral tracings and intraoral recording materials. This study compared horizontal condylar inclination angles (HCI) recorded with a protrusive interocclusal record and an electronic pantographic device, the Jaw Motion Analyzer (JMA).

MATERIALS AND METHODS

Twenty-three volunteers (12 females; 11 males; mean age 46.7 years) were selected for this study. First, a protrusive interocclusal wax record after 5 mm protrusive movement was taken from the volunteers and the HCI angles were determined after mounting the volunteers' casts in 2 different articulators (SAM 2; Reference SL). Second, kinematic hinge axis and the HCIs were recorded after 5 mm protrusive movement from protrusive jaw tracks recorded with the JMA. ICC and mean values for HCI were used for statistical analysis. Mean differences of HCI between the measuring methods were compared by Bland Altman Plots.

RESULTS

The agreement of the HCI between the articulators determined by the protrusive record was good. The mean HCI value recorded with the JMA was significantly higher compared to the values of the protrusive wax records. There was no agreement found between the different methods for calculating the HCI.

CONCLUSION

A large variance in articulator settings obtained by interocclusal records is often found. The JMA was found reliable and valid for measuring HCI values. Within the limitations of this study, the use of a pantographic device should be considered for individually adjusting articulators rather than the use of protrusive records.

摘要

目的

记录下颌前伸运动的基本原理是精确调整牙合架。记录髁突倾斜度的技术包括口外描记法和口内记录材料。本研究比较了用前伸牙合记录和电子全口义齿运动描记装置(下颌运动分析仪,JMA)记录的水平髁突倾斜角(HCI)。

材料与方法

本研究选取了23名志愿者(12名女性,11名男性;平均年龄46.7岁)。首先,让志愿者进行5mm前伸运动后制取前伸牙合蜡记录,将志愿者的模型安装在2种不同的牙合架(SAM 2;参考SL)上后测定HCI角。其次,从用JMA记录的前伸颌轨迹中获取5mm前伸运动后的运动铰链轴和HCI。采用组内相关系数(ICC)和HCI的平均值进行统计分析。通过Bland Altman图比较测量方法之间HCI的平均差异。

结果

由前伸记录确定的牙合架之间HCI的一致性良好。与前伸蜡记录的值相比,用JMA记录的平均HCI值显著更高。计算HCI的不同方法之间未发现一致性。

结论

通常发现通过牙合记录获得的牙合架设置存在很大差异。发现JMA在测量HCI值方面可靠且有效。在本研究的局限性内,应考虑使用全口义齿运动描记装置来单独调整牙合架,而不是使用前伸记录。