Cerviño Alejandro, Hosking Sarah L, Montés-Micó Robert, Alió Jorge L
Department of Optics, University of Valencia, Valencia, Spain.
J Cataract Refract Surg. 2008 Mar;34(3):441-6. doi: 10.1016/j.jcrs.2007.11.021.
To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs.
Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri. Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes.
All measured values were similar between the monofocal and multifocal groups. Contrast sensitivity correlated significantly with the retinal straylight value (r= 0.258; P= .026) and the mean residual spherical equivalent. There was no statistically significant relationship between IOL type and the retinal straylight value (P= .089). Adjusted mean scores suggest that straylight values in the monofocal group were slightly higher than in the multifocal group. In the monofocal group, retinal straylight values were significantly correlated with pupil size (r= -0.377; P= .033). In the multifocal group, a correlation was found between retinal straylight values and contrast sensitivity (r= 0.397; P= .024). After controlling for age differences, there were no significant differences in retinal straylight between IOLs (P= .069).
No significant differences in straylight values were found between multifocal IOLs and monofocal IOLs. Pupil miosis during retinal straylight measurement and neural adaptation after multifocal IOL implantation may overcome differences between IOLs.
确定单焦点人工晶状体(IOL)患者与多焦点IOL患者所感知的视网膜杂散光差异。
西班牙阿利坎特市的Vissum-阿利坎特眼科研究所。
在这项前瞻性研究中,对40名单焦点或多焦点IOL患者的67只眼在术后6个月前瞻性地测量了对比敏感度和视网膜杂散光。在单焦点组中,12只眼植入了ThinOptX IOL(ThinOptX公司),20只眼植入了Acri.Smart 48 S IOL(Acri.Tec公司)。在多焦点IOL组中,13只眼植入了ReZoom IOL(Advanced Medical Optics公司),22只眼植入了ReSTOR IOL(爱尔康实验室公司)。
单焦点组和多焦点组之间所有测量值均相似。对比敏感度与视网膜杂散光值(r = 0.258;P = 0.026)和平均残余球镜当量显著相关。IOL类型与视网膜杂散光值之间无统计学显著关系(P = 0.089)。调整后的平均得分表明,单焦点组的杂散光值略高于多焦点组。在单焦点组中,视网膜杂散光值与瞳孔大小显著相关(r = -0.377;P = 0.033)。在多焦点组中,发现视网膜杂散光值与对比敏感度之间存在相关性(r = 0.397;P = 0.024)。在控制年龄差异后,不同IOL之间的视网膜杂散光无显著差异(P = 0.069)。
多焦点IOL和单焦点IOL之间在杂散光值上未发现显著差异。视网膜杂散光测量期间的瞳孔缩小以及多焦点IOL植入后的神经适应可能会克服不同IOL之间的差异。