Ortiz Dolores, Alió Jorge L, Bernabéu Gonzalo, Pongo Vanessa
Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
J Cataract Refract Surg. 2008 May;34(5):755-62. doi: 10.1016/j.jcrs.2007.12.038.
To study the optical performance of intraocular lenses (IOLs) in the human eye to ascertain how multifocality affects the optical performance of refractive and diffractive technologies and the relationship to pupil size.
Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
Ten eyes each received the monofocal AcrySof MA60 IOL (Alcon) or 1 of the following multifocal pupil-dependent IOLs: diffractive AcrySof ReSTOR (Alcon) or refractive ReZoom (Advanced Medical Optics). The intraocular optical quality in vivo with 3.0 mm and 5.0 mm pupils was characterized by comparing the means of the difference between the total and corneal optical aberrations 3 months postoperatively. The main outcomes measures were total, higher-order, spherical, and coma aberrations (root-mean-square values); modulation transfer function values; point-spread function; and the Strehl ratio.
The ReZoom group had higher in vivo intraocular aberrations than the AcrySof ReSTOR and AcrySof MA60 groups (P = .022). The difference in spherical aberration between the AcrySof ReSTOR and ReZoom groups was statistically significant with 5.0 mm pupils (P = .003) and 3.0 mm pupils (P = .001). The AcrySof ReSTOR group had statistically significant lower coma aberration values with a 5.0 mm pupil (P = .012); there were no differences between IOLs with a 3.0 mm pupil (P = .185).
Multifocal refractive IOLs resulted in higher intraocular aberrations. The hybrid refractive-diffractive IOL was the least affected by pupil diameter in terms of intraocular aberrations and showed significantly less increase in optical aberrations when the pupil was enlarged.
研究人工晶状体(IOL)在人眼中的光学性能,以确定多焦点特性如何影响折射和衍射技术的光学性能以及与瞳孔大小的关系。
西班牙阿利坎特市维苏姆眼科研究所。
10只眼睛分别植入单焦点AcrySof MA60人工晶状体(爱尔康公司)或以下多焦点瞳孔依赖型人工晶状体中的一种:衍射型AcrySof ReSTOR(爱尔康公司)或折射型ReZoom(先进医学光学公司)。通过比较术后3个月时总像差与角膜像差差值的均值,对3.0mm和5.0mm瞳孔下的眼内光学质量进行表征。主要观察指标为总像差、高阶像差、球差和彗差(均方根值);调制传递函数值;点扩散函数;以及斯特列尔比。
ReZoom组的眼内像差高于AcrySof ReSTOR组和AcrySof MA60组(P = 0.022)。AcrySof ReSTOR组和ReZoom组之间的球差差异在5.0mm瞳孔时具有统计学意义(P = 0.003),在3.0mm瞳孔时也具有统计学意义(P = 0.001)。AcrySof ReSTOR组在5.0mm瞳孔时彗差值具有统计学意义的降低(P = 0.012);在3.0mm瞳孔时各人工晶状体之间无差异(P = 0.185)。
多焦点折射型人工晶状体导致更高的眼内像差。混合折射 - 衍射型人工晶状体在眼内像差方面受瞳孔直径影响最小,并且在瞳孔扩大时光学像差的增加明显较少。