Suppr超能文献

单层扰相梯度回波成像中的MT效应与T1定量分析

MT effects and T1 quantification in single-slice spoiled gradient echo imaging.

作者信息

Ou Xiawei, Gochberg Daniel Frank

机构信息

Department of Radiology, Vanderbilt University Institute of Imaging Science, Nashville, Tennessee 37232-2310, USA.

出版信息

Magn Reson Med. 2008 Apr;59(4):835-45. doi: 10.1002/mrm.21550.

Abstract

We investigated magnetization transfer (MT) effects on the steady-state MR signal for a sample subjected to a series of identical on-resonance RF pulses, such as would be experienced while imaging a single slice using a spoiled gradient echo sequence. The MT coupling terms for a two-pool system were added to the Bloch equations and we derived the resulting steady-state signal equation and compared this result to the conventional signal equation without MT effects. The steady-state signal is increased by a few percent of the equilibrium magnetization because of MT. One consequence of this MT effect is inaccuracy in T(1) values determined via conventional steady-state gradient echo methods. (Theory predicts greater than 10% errors in T(1) for white matter when using short TR.) A second consequence is the ability to quantify the relaxation and MT parameters by fitting the gradient echo steady state signal to the signal equation appropriately modified to include MT effects. The theory was tested in samples of MnCl(2), cross-linked bovine serum albumin (BSA), and cross-linked BSA + MnCl(2).

摘要

我们研究了磁化传递(MT)对处于一系列相同共振射频脉冲作用下的样品的稳态磁共振信号的影响,这种情况类似于使用扰相梯度回波序列对单个层面成像时所经历的情况。将双池系统的MT耦合项添加到布洛赫方程中,我们推导出了所得的稳态信号方程,并将此结果与无MT效应的传统信号方程进行比较。由于MT的作用,稳态信号比平衡磁化强度增加了百分之几。这种MT效应的一个后果是,通过传统稳态梯度回波方法测定的T(1)值不准确。(理论预测,使用短TR时,白质的T(1)误差大于10%。)第二个后果是能够通过将梯度回波稳态信号拟合到经适当修改以包含MT效应的信号方程来量化弛豫和MT参数。该理论在MnCl(2)、交联牛血清白蛋白(BSA)以及交联BSA + MnCl(2)样品中进行了验证。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0cfc/4186261/88f513751293/nihms176375f1.jpg

相似文献

8
Effects of slow flow on slice profile and NMR signal in fast imaging sequences.
Phys Med Biol. 1994 Sep;39(9):1489-500. doi: 10.1088/0031-9155/39/9/013.

引用本文的文献

4
Assessment of accuracy and repeatability of quantitative parameter mapping in MRI.MRI 中定量参数图的准确性和可重复性评估。
Radiol Phys Technol. 2024 Dec;17(4):918-928. doi: 10.1007/s12194-024-00836-4. Epub 2024 Aug 28.

本文引用的文献

10
Quantitative imaging of magnetization transfer using multiple selective pulses.使用多个选择性脉冲的磁化传递定量成像。
Magn Reson Med. 1999 May;41(5):1065-72. doi: 10.1002/(sici)1522-2594(199905)41:5<1065::aid-mrm27>3.0.co;2-9.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验