使用双团注注射技术在首次通过磁共振灌注成像期间估计绝对心肌血流量:与单团注注射方法的比较。

Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method.

作者信息

Christian Timothy F, Aletras Anthony H, Arai Andrew E

机构信息

Department of Medicine, University of Vermont College of Medicine, Burlington, Vermont 05495, USA.

出版信息

J Magn Reson Imaging. 2008 Jun;27(6):1271-7. doi: 10.1002/jmri.21383.

Abstract

PURPOSE

To compare the dual-bolus to single-bolus quantitative first-pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF).

MATERIALS AND METHODS

Dogs had local hyperemia of MBF in the left anterior descending (LAD) coronary artery (intracoronary adenosine). Animals (n = 6) had sequential single- and dual-bolus perfusion studies with microsphere determination of absolute MBF. Perfusion imaging was performed using a saturation-recovery gradient-echo sequence. Absolute MBF was by Fermi function deconvolution and compared to transmural, endocardial, and epicardial microsphere values in the same region of interest (ROI).

RESULTS

Signal and contrast were significantly higher for the dual-bolus perfusion images. The correlation with MBF by microspheres was r = 0.94 for the dual-bolus method and r = 0.91 for the single-bolus method. There was no significant difference between MRI and microsphere MBF values for control or hyperemic zones for transmural segments for either technique. When the ROI was reduced to define endocardial and epicardial zones, single-bolus MR first-pass imaging significantly overestimated MBF and had a significantly larger absolute error vs. microspheres when compared to dual-bolus perfusion.

CONCLUSION

Both single-bolus and dual-bolus perfusion methods correlate closely with MBF but the signal and contrast of the dual-bolus images are greater. With smaller nontransmural ROIs where signal is reduced, the dual-bolus method appeared to provide slightly more accurate results.

摘要

目的

比较双团注与单团注定量首过磁共振心肌灌注成像对绝对心肌血流量(MBF)的评估。

材料与方法

犬左前降支(LAD)冠状动脉局部充血(冠状动脉内注射腺苷)。动物(n = 6)先后进行单团注和双团注灌注研究,通过微球法测定绝对MBF。使用饱和恢复梯度回波序列进行灌注成像。通过费米函数反卷积计算绝对MBF,并与同一感兴趣区域(ROI)的透壁、心内膜和心外膜微球值进行比较。

结果

双团注灌注图像的信号和对比度显著更高。双团注法与微球法测定的MBF的相关性为r = 0.94,单团注法为r = 0.91。两种技术在对照或充血区域的透壁节段,MRI与微球MBF值之间均无显著差异。当缩小ROI以定义心内膜和心外膜区域时,与双团注灌注相比,单团注磁共振首过成像显著高估了MBF,且与微球法相比绝对误差显著更大。

结论

单团注和双团注灌注方法与MBF均密切相关,但双团注图像的信号和对比度更高。在信号降低的较小非透壁ROI中,双团注法似乎能提供稍更准确的结果。