优化血流介导的血管舒张临床研究中可重复性和效能的方法学途径。

Methodological approaches to optimize reproducibility and power in clinical studies of flow-mediated dilation.

作者信息

Donald Ann E, Halcox Julian P, Charakida Marietta, Storry Clare, Wallace Sharon M L, Cole Tim J, Friberg Peter, Deanfield John E

机构信息

Vascular Physiology Unit, UCL Institute of Child Health, London, United Kingdom.

出版信息

J Am Coll Cardiol. 2008 May 20;51(20):1959-64. doi: 10.1016/j.jacc.2008.02.044.

Abstract

OBJECTIVES

Our aim was to determine reproducibility of the flow-mediated dilation (FMD) response profile, and discriminatory ability of the components.

BACKGROUND

Brachial FMD is widely used to study conduit artery endothelial function. Automated B-mode image edge detection (B-ED) provides a full response profile. Reproducibility and biological relevance of these additional components have not been fully explored.

METHODS

Forty-two healthy adults underwent FMD using B-ED repeated at fixed time intervals up to 3 months. The FMD profile was assessed for diameter changes, area under the curve, and time course. Measures were compared in 25 adults with hypercholesterolemia, 25 subjects with diabetes, and 50 matched control subjects.

RESULTS

The maximum change in FMD was the most reproducible (coefficient of variation = 9.8%, 10.6%, 6.6%, and 9.2% at 4 to 6 h, 1 week, 1 month, and 3 months, respectively). Most of the variability occurred between subjects rather than within. All FMD measures except time course were significantly reduced in hypercholesterolemia and diabetes. Power curves were generated to indicate the appropriate number of subjects for parallel and crossover study designs.

CONCLUSIONS

Maximum FMD percentage change from baseline is the most reproducible of the response curve measures and best identifies those with risk factors. Flow-mediated dilation measured by B-ED is robust and practical to assess the effect of interventions on endothelial function in clinical trials.

摘要

目的

我们的目的是确定血流介导的血管舒张(FMD)反应曲线的可重复性以及各组成部分的鉴别能力。

背景

肱动脉FMD被广泛用于研究传导动脉的内皮功能。自动B型图像边缘检测(B-ED)可提供完整的反应曲线。这些额外组成部分的可重复性和生物学相关性尚未得到充分探索。

方法

42名健康成年人使用B-ED进行FMD检测,并在长达3个月的固定时间间隔重复检测。对FMD曲线进行直径变化、曲线下面积和时间过程的评估。对25名高胆固醇血症成年人、25名糖尿病患者和50名匹配的对照受试者的测量结果进行比较。

结果

FMD的最大变化是最具可重复性的(在4至6小时、1周、1个月和3个月时的变异系数分别为9.8%、10.6%、6.6%和9.2%)。大部分变异性存在于受试者之间而非受试者内部。除时间过程外,所有FMD测量值在高胆固醇血症和糖尿病患者中均显著降低。生成功效曲线以表明平行和交叉研究设计所需的合适受试者数量。

结论

FMD相对于基线的最大百分比变化是反应曲线测量中最具可重复性的,并且能最好地识别有危险因素的个体。通过B-ED测量的血流介导的血管舒张在评估临床试验中干预措施对内皮功能的影响方面是可靠且实用的。