Ophir J, Céspedes I, Ponnekanti H, Yazdi Y, Li X
Department of Radiology, University of Texas Medical School, Houston 77030.
Ultrason Imaging. 1991 Apr;13(2):111-34. doi: 10.1177/016173469101300201.
We describe a new method for quantitative imaging of strain and elastic modulus distributions in soft tissues. The method is based on external tissue compression, with subsequent computation of the strain profile along the transducer axis, which is derived from cross-correlation analysis of pre- and post-compression A-line pairs. The strain profile can then be converted to an elastic modulus profile by measuring the stresses applied by the compressing device and applying certain corrections for the nonuniform stress field. We report initial results of several phantom and excised animal tissue experiments which demonstrate the ability of this technique to quantitatively image strain and elastic modulus distributions with good resolution, sensitivity and with diminished speckle. We discuss several potential clinical uses of this technique.
我们描述了一种用于软组织应变和弹性模量分布定量成像的新方法。该方法基于外部组织压缩,随后沿换能器轴计算应变分布,这是通过对压缩前后A线对进行互相关分析得出的。然后,通过测量压缩装置施加的应力并对非均匀应力场进行某些校正,可将应变分布转换为弹性模量分布。我们报告了几个体模和切除动物组织实验的初步结果,这些结果证明了该技术能够以良好的分辨率、灵敏度和减少的散斑对应变和弹性模量分布进行定量成像。我们讨论了该技术的几种潜在临床应用。