The aim of this randomized, placebo-controlled, double-blind study was to assess whether a low frequency magnetic field can influence pain intensity, quality of life and sleep, and glycaemic control in patients with painful diabetic polyneuropathy.
Sixty-one patients were randomized into two groups: the study group comprised 32 patients exposed to a low frequency magnetic field, average pain duration 23 months; the control group included 29 patients who received sham exposure, average pain duration 28 months. Patients were exposed for three weeks, 20 min a day, five days a week. The magnetic field generator was a Viofor JPS device (Med & Life, Komorow, Poland). All subjects filled out the following questionnaires five times (at the beginning and after one, two, three and five weeks): SFMPQ-VAS (pain evaluation), EuroQol EQ-5D and MOS Sleep Scale. HbA(1c) was evaluated at baseline and after five weeks.
Significant reductions in pain intensity were seen in both the study group (visual analogue scale [VAS] value of 73 mm at baseline versus 33 mm after three weeks) and controls (VAS 69 mm at baseline versus 41 mm after three weeks). The extent of pain reduction did not differ significantly between the groups at any time. Also, both groups had similar improvements in EuroQol, MOS and HbA(1c) values.
Genuine magnetic field exposure has no advantage over sham exposure in reducing pain intensity, improving quality of life, and decreasing sleep disturbances and HbA(1c).
本随机、安慰剂对照、双盲研究旨在评估低频磁场是否会影响痛性糖尿病性多发性神经病患者的疼痛强度、生活质量、睡眠及血糖控制。
61例患者被随机分为两组:研究组32例,暴露于低频磁场,平均疼痛持续时间23个月;对照组29例,接受假暴露,平均疼痛持续时间28个月。患者暴露三周,每天20分钟,每周五天。磁场发生器为Viofor JPS设备(Med & Life,科莫罗夫,波兰)。所有受试者五次填写以下问卷(开始时以及1、2、3和5周后):SFMPQ-VAS(疼痛评估)、欧洲五维度健康量表(EuroQol EQ-5D)和MOS睡眠量表。在基线及5周后评估糖化血红蛋白(HbA1c)。
研究组(基线时视觉模拟量表[VAS]值为73 mm,三周后为33 mm)和对照组(基线时VAS为69 mm,三周后为41 mm)的疼痛强度均显著降低。两组在任何时间的疼痛减轻程度均无显著差异。此外,两组在欧洲五维度健康量表、MOS及HbA1c值方面均有相似改善。
在减轻疼痛强度、改善生活质量、减少睡眠障碍及降低HbA1c方面,真磁场暴露与假暴露相比并无优势。