Pai Madhukar, Zwerling Alice, Menzies Dick
McGill University and Montreal Chest Institute, Montreal, Quebec, Canada.
Ann Intern Med. 2008 Aug 5;149(3):177-84. doi: 10.7326/0003-4819-149-3-200808050-00241. Epub 2008 Jun 30.
Interferon-gamma-release assays (IGRAs) are alternatives to the tuberculin skin test (TST). A recent meta-analysis showed that IGRAs have high specificity, even among populations that have received bacille Calmette-Guérin (BCG) vaccination. Sensitivity was suboptimal for TST and IGRAs.
To incorporate newly reported evidence from 20 studies into an updated meta-analysis on the sensitivity and specificity of IGRAs.
PubMed was searched through 31 March 2008, and citations of all original articles, guidelines, and reviews for studies published in English were reviewed.
Studies that evaluated QuantiFERON-TB Gold, QuantiFERON-TB Gold In-Tube (both from Cellestis, Victoria, Australia), and T-SPOT.TB (Oxford Immunotec, Oxford, United Kingdom) or its precommercial ELISpot version, when data on the commercial version were lacking. For assessing sensitivity, the study sample had to have microbiologically confirmed active tuberculosis. For assessing specificity, the sample had to comprise healthy, low-risk individuals without known exposure to tuberculosis. Studies with fewer than 10 participants and those that included only immunocompromised participants were excluded.
One reviewer abstracted data on participant characteristics, test characteristics, and test performance from 38 studies; these data were double-checked by a second reviewer. The original investigators were contacted for additional information when necessary.
A fixed-effects meta-analysis with correction for overdispersion was done to pool data within prespecified subgroups. The pooled sensitivity was 78% (95% CI, 73% to 82%) for QuantiFERON-TB Gold, 70% (CI, 63% to 78%) for QuantiFERON-TB Gold In-Tube, and 90% (CI, 86% to 93%) for T-SPOT.TB. The pooled specificity for both QuantiFERON tests was 99% among non-BCG-vaccinated participants (CI, 98% to 100%) and 96% (CI, 94% to 98%) among BCG-vaccinated participants. The pooled specificity of T-SPOT.TB (including its precommercial ELISpot version) was 93% (CI, 86% to 100%). Tuberculin skin test results were heterogeneous, but specificity in non-BCG-vaccinated participants was consistently high (97% [CI, 95% to 99%]).
Most studies were small and had limitations, including no gold standard for diagnosing latent tuberculosis and variable TST methods and cutoff values. Data on the specificity of the commercial T-SPOT.TB assay were limited.
The IGRAs, especially QuantiFERON-TB Gold and QuantiFERON-TB Gold In-Tube, have excellent specificity that is unaffected by BCG vaccination. Tuberculin skin test specificity is high in non-BCG-vaccinated populations but low and variable in BCG-vaccinated populations. Sensitivity of IGRAs and TST is not consistent across tests and populations, but T-SPOT.TB appears to be more sensitive than both QuantiFERON tests and TST.
γ-干扰素释放试验(IGRAs)是结核菌素皮肤试验(TST)的替代方法。最近的一项荟萃分析表明,即使在接种过卡介苗(BCG)的人群中,IGRAs也具有很高的特异性。TST和IGRAs的敏感性都不太理想。
将20项研究新报道的证据纳入关于IGRAs敏感性和特异性的更新荟萃分析。
检索了截至2008年3月31日的PubMed,并对所有以英文发表的原始文章、指南和综述的参考文献进行了审查。
评估结核感染T细胞检测(QuantiFERON-TB Gold)、全血γ-干扰素释放检测(QuantiFERON-TB Gold In-Tube,均来自澳大利亚维多利亚州的Cellestis公司)以及T-SPOT.TB(英国牛津的Oxford Immunotec公司)或其商业化前的酶联免疫斑点法(ELISpot)版本的研究,前提是缺乏商业化版本的数据。为评估敏感性,研究样本必须有微生物学确诊的活动性结核病。为评估特异性,样本必须包括健康、低风险且无已知结核暴露史的个体。参与者少于10人的研究以及仅纳入免疫功能低下参与者的研究被排除。
一名审阅者从38项研究中提取了关于参与者特征、检测特征和检测性能的数据;这些数据由另一名审阅者进行了二次核对。必要时与原始研究者联系以获取更多信息。
采用固定效应荟萃分析并校正过度离散,以汇总预先指定亚组内的数据。结核感染T细胞检测的汇总敏感性为78%(95%CI,73%至82%),全血γ-干扰素释放检测为70%(CI,63%至78%),T-SPOT.TB为90%(CI,86%至93%)。两种结核感染T细胞检测在未接种卡介苗的参与者中的汇总特异性为99%(CI,98%至100%),在接种卡介苗的参与者中为96%(CI,94%至98%)。T-SPOT.TB(包括其商业化前的ELISpot版本)的汇总特异性为93%(CI,86%至100%)。结核菌素皮肤试验结果存在异质性,但在未接种卡介苗的参与者中特异性始终较高(97%[CI,95%至99%])。
大多数研究规模较小且存在局限性,包括缺乏诊断潜伏性结核的金标准以及结核菌素皮肤试验方法和临界值的差异。商业化T-SPOT.TB检测特异性的数据有限。
IGRAs,尤其是结核感染T细胞检测和全血γ-干扰素释放检测,具有不受卡介苗接种影响的出色特异性。结核菌素皮肤试验在未接种卡介苗的人群中特异性较高,但在接种卡介苗的人群中较低且存在差异。IGRAs和结核菌素皮肤试验的敏感性在不同检测和人群中不一致,但T-SPOT.TB似乎比两种结核感染T细胞检测和结核菌素皮肤试验更敏感。