Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable.
Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced.
All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful.
The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.
由于基于微光电二极管的视网膜下视觉假体能量水平较低,外部电源是必不可少的。我们报告了一种通过经巩膜、经脉络膜电缆将视网膜下假体与耳后间隙的体外连接器相连的方法中眼外部分的手术可行性和功能结果。
7名患有色素性视网膜炎的志愿者接受了有源视网膜下植入物;能量由经巩膜、经脉络膜植入的聚酰亚胺箔上的金线提供,金线通向眶外侧缘,在那里固定并连接到硅胶电缆。使用套管针将电缆骨膜下植入颞肌下方至耳后间隙,在那里它穿透皮肤以连接到刺激器。为避免植入物在视网膜下移动,引入了三个应力释放点。
所有植入均按计划进行,无并发症,术后期间未发生严重不良事件。在整个4周的研究期间,植入物的固定稳定;永久性皮肤穿透证明并不复杂。下视和外展/内收时眼球运动受限最小。取出过程顺利。
上述程序提供了一种通过经巩膜、经脉络膜电缆连接将视网膜下装置稳定固定到体外连接器的方法。