Wen Chun-Yi, Qin Ling, Lee Kwong-Man, Chan Kai-Ming
Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China.
Bone. 2009 Sep;45(3):545-52. doi: 10.1016/j.bone.2008.08.112. Epub 2008 Aug 22.
The present study was designed to compare peri-graft bone mass and microarchitecture with tendon-to-bone (T-B) attachment strength after anterior cruciate ligament (ACL) reconstruction in a rabbit model. Surgical reconstruction using digital extensor tendon in bone tunnel was performed on 58 rabbits. Forty-two of the 58 rabbits were sacrificed at week 0, 2, 6 and 12 after operation respectively. The femur-graft-tibia complexes were harvested for pQCT and micro-CT examination to characterize the spatiotemporal changes of peri-graft bone in T-B healing in conjunction with histological examination. The remaining 16 rabbits were euthanized at week 6 and 12 postoperatively (i.e. 8 rabbits for each time point) for pull-out test after micro-CT examination to investigate the relationship between the T-B attachment strength and peri-graft bone mass/microarchitecture. Peri-graft BMD, BV/TV and connectivity was significantly lower at week 6 than those at time zero although there were no significant changes detected in the first 2 postoperative weeks. In addition, peri-graft bone mass and connectivity was significantly lower on the tibial side than those on the femoral side; and osteoclasts accumulated on the surface of peri-graft bone. Grafted tendon was prone to be pulled out from the tibial tunnel with bone attachment; the weakest point of the complexes shifted from the healing interface at time zero to peri-graft bone at week 6 after operation. With reverse of peri-graft bone at week 12 postoperatively, the weakest point shifted to the intra-osseous tendinous portion. The stiffness of T-B attachment correlated with peri-graft BV/TV (r2 = 0.68, p = 0.001) and connectivity (r2 = 0.47, p = 0.013) at week 6 after operation. T-B healing was a highly dynamic process of emergence and maintenance of peri-graft bone. T-B attachment strength was in relation to peri-graft bone mass and connectivity after ACL reconstruction. The measurement of peri-graft bone should be useful to monitor the quality of T-B healing and guide the postoperative rehabilitation.
本研究旨在比较兔前交叉韧带(ACL)重建术后移植物周围骨量和微观结构与肌腱-骨(T-B)附着强度。对58只兔进行了在骨隧道中使用指伸肌腱的手术重建。58只兔中的42只分别在术后第0、2、6和12周处死。采集股骨-移植物-胫骨复合体进行外周定量计算机断层扫描(pQCT)和微观计算机断层扫描(micro-CT)检查,以结合组织学检查来表征T-B愈合过程中移植物周围骨的时空变化。其余16只兔在术后第6和12周实施安乐死(即每个时间点8只兔),在micro-CT检查后进行拔出试验,以研究T-B附着强度与移植物周围骨量/微观结构之间的关系。尽管术后前2周未检测到显著变化,但术后第6周移植物周围骨密度、骨体积分数(BV/TV)和连通性显著低于术后即刻。此外,移植物周围胫骨侧的骨量和连通性显著低于股骨侧;并且破骨细胞在移植物周围骨表面积聚。移植的肌腱易于从带有骨附着的胫骨隧道中拔出;复合体的最薄弱点从术后即刻的愈合界面转移到术后第6周的移植物周围骨。术后第12周移植物周围骨逆转时,最薄弱点转移到骨内肌腱部分。术后第6周,T-B附着的刚度与移植物周围BV/TV(r2 = 0.68,p = 0.001)和连通性(r2 = 0.47,p = 0.013)相关。T-B愈合是移植物周围骨出现和维持的高度动态过程。ACL重建术后T-B附着强度与移植物周围骨量和连通性有关。移植物周围骨的测量对于监测T-B愈合质量和指导术后康复应是有用的。