Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease.

作者信息

Nissen S E, Gurley J C, Grines C L, Booth D C, McClure R, Berk M, Fischer C, DeMaria A N

机构信息

Division of Cardiovascular Medicine, University of Kentucky Medical Center, Lexington 40536-0084.

出版信息

Circulation. 1991 Sep;84(3):1087-99. doi: 10.1161/01.cir.84.3.1087.

Abstract

BACKGROUND

Necropsy studies demonstrate that coronary artery disease (CAD) is frequently complex and eccentric. However, angiography provides only a silhouette of the vessel lumen. Intravascular ultrasound is a new tomographic imaging method for evaluation of coronary dimensions and wall morphology. Few data exist regarding intravascular ultrasound in patients with CAD, and no data exist for subjects with normal coronaries.

METHODS AND RESULTS

We used a multielement 5.5F, 20-MHz ultrasound catheter to examine eight normal subjects and 43 patients with CAD. We assessed the safety of coronary ultrasound and the effect of vessel eccentricity on comparison of minimum luminal diameter by angiography and ultrasound. Normal and atherosclerotic wall morphology and stenosis severity were also evaluated by intravascular ultrasound. The only untoward effect was transient coronary spasm in five patients. At 33 sites in normal subjects, the lumen was nearly circular, yielding a close correlation between angiographic and ultrasonic minimum diameter (r = 0.92). At 90 sites in patients with CAD, ultrasound demonstrated a concentric cross section; correlation was also close (r = 0.93). However, at 72 eccentric sites, correlation was not as close (r = 0.77). For 41 stenoses, correlation between angiography and ultrasound for area reduction was moderate (r = 0.63). In normal subjects, wall morphology revealed a thin (0.30 mm or less) intimal leading edge and subadjacent sonolucent zone (0.20 mm or less). Patients with CAD exhibited increased thickness and echogenicity of the leading edge, thickened sonolucent zones, and/or attenuation of ultrasound transmission.

CONCLUSIONS

These data establish that intravascular ultrasound is feasible and safe and yields luminal measurements that correlate generally with angiography. Differences between angiographic and ultrasound measures of lumen size in eccentric vessels probably reflect the dissimilar perspectives of tomographic and silhouette imaging techniques. Intravascular ultrasound provides detailed images of normal and abnormal wall morphology not previously possible in vivo.