Suppr超能文献

与电子计时相比,手持秒表在测量短跑成绩时的可靠性和准确性。

Reliability and accuracy of handheld stopwatches compared with electronic timing in measuring sprint performance.

作者信息

Hetzler Ronald K, Stickley Christopher D, Lundquist Kelly M, Kimura Iris F

机构信息

Department of Kinesiology and Leisure Science, Human Performance Lab, University of Hawaii-Manoa, Honolulu, Hawaii, USA.

出版信息

J Strength Cond Res. 2008 Nov;22(6):1969-76. doi: 10.1519/JSC.0b013e318185f36c.

Abstract

This study assessed reliability of split times obtained by handheld stopwatches (HHSs) compared with electronic timing (ET) during a 200-m sprint. Two HHS timing methods were compared with ET: single-split timers (SST) and multiple-split timers (MST). Twenty-six timers without previous experience were given instruction and completed practice trials until good agreement was achieved between ET and HHS. Trained runners (8 males, 10 females) were timed for each 25-m interval on a standard 200-m course. Repeated-measures analysis of variance and intraclass correlation models were used to determine reliability. A total of 248 split times were analyzed. No significant differences were found between the three timing methods (p > 0.99), and calculated intraclass correlation values were high (0.988). Mean error between SST, MST, and ET (-0.04 +/- 0.24 and -0.05 +/- 0.24 seconds, respectively) indicated faster HHS times, though not significantly. However, absolute errors were considerably larger (0.15 +/- 0.20 and 0.16 +/- 0.19 between SST, MST, and ET, respectively). The HHS-recorded splits were faster than ET in 67.3% of splits and slower in 29.4%. The distribution of errors made the development of a reliable correction factor to convert HHS to ET impossible. It was concluded that on the basis of the small mean error and high intraclass correlations, the use of HHSs may be a viable alternative to ET in collecting group data. However, on the basis of the absolute error between HHS and ET, when high degrees of precision are required, ET should be used, and reliable correction of HHS to ET values is not possible. It was further concluded that HHS times should be reported without attempting correction and interpreted in light of the shortcomings of the HHS method.

摘要

本研究评估了在200米短跑过程中,与电子计时(ET)相比,手持秒表(HHS)所记录的分段时间的可靠性。将两种HHS计时方法与ET进行了比较:单分段计时器(SST)和多分段计时器(MST)。26名没有相关经验的计时员接受了指导并完成了练习试验,直到ET和HHS之间达成良好的一致性。在标准的200米赛道上,对训练有素的跑步者(8名男性,10名女性)的每25米间隔进行计时。采用重复测量方差分析和组内相关模型来确定可靠性。共分析了248个分段时间。三种计时方法之间未发现显著差异(p>0.99),计算得出的组内相关值较高(0.988)。SST、MST和ET之间的平均误差(分别为-0.04±0.24秒和-0.05±0.24秒)表明HHS记录的时间更快,尽管不显著。然而,绝对误差要大得多(SST、MST和ET之间分别为0.15±0.20和0.16±0.19)。HHS记录的分段时间在67.3%的分段中比ET快,在29.4%的分段中比ET慢。误差分布使得开发一个可靠的将HHS转换为ET的校正因子变得不可能。得出的结论是,基于较小的平均误差和较高的组内相关性,在收集群体数据时,使用HHS可能是ET的一个可行替代方案。然而,基于HHS和ET之间的绝对误差,当需要高精度时,应使用ET,并且无法将HHS可靠地校正为ET值。进一步得出的结论是,应报告HHS记录的时间,而无需尝试校正,并根据HHS方法的缺点进行解释。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验