The introduction of 'compact' accelerator mass spectrometers into biomedical science, including use in drug metabolism and bioanalytical applications, is an exciting recent development. Comparisons are presented here between a more established and relatively large tandem accelerator which operates at up to 5 MV and a conventional laboratory-sized 250 kV single-stage accelerator mass spectrometer. Biological samples were enriched with low levels of radiocarbon, then converted into graphite prior to analysis on each of the two instruments. The data obtained showed the single-stage instrument to be capable of delivering comparable results, and thus able to provide similar study support, with that provided by the 5 MV instrument, without the significant overheads and complexities which are inherent to the operation of the larger instrument. We believe that the advent of these laboratory-sized accelerator mass spectrometry (AMS) instruments represents a real turning point in the potential for application of AMS by a wider user group.

摘要

“紧凑型”加速器质谱仪引入生物医学科学领域,包括用于药物代谢和生物分析应用,是近期一项令人兴奋的进展。本文对一台运行电压高达5兆伏的成熟且相对大型的串联加速器与一台传统实验室规模的250千伏单级加速器质谱仪进行了比较。生物样品先用低水平放射性碳进行富集,然后在这两台仪器上分别进行分析之前转化为石墨。所获得的数据表明,单级仪器能够给出可比的结果,因此能够提供与5兆伏仪器相似的研究支持,且没有大型仪器运行所固有的巨大开销和复杂性。我们认为,这些实验室规模的加速器质谱(AMS)仪器的出现,对于更广泛用户群体应用AMS的潜力而言,是一个真正的转折点。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验