Suppr超能文献

多孔表面与粗糙表面纯钛种植体的组织形态计量学分析

Histomorphometric analysis of pure titanium implants with porous surface versus rough surface.

作者信息

Brentel Aline Scalone, de Vasconcellos Luana Marotta Reis, Oliveira Marize Varella, Graça Mário Lima de Alencastro, de Vasconcellos Luis Gustavo Oliveira, Cairo Carlos Alberto Alves, Carvalho Yasmin Rodarte

机构信息

Department of Bioscience and Buccal Diagnosis, São José dos Campos Dental School, State University of São Paulo (UNESP), São José dos Campos, SP, Brazil.

出版信息

J Appl Oral Sci. 2006 Jun;14(3):213-8. doi: 10.1590/s1678-77572006000300013.

Abstract

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 +/- 1.00% and 65.05 +/- 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.

摘要

本研究的目的是分析采用粉末冶金技术制造的具有粗糙和多孔表面的商业纯钛植入物植入兔胫骨后周围的骨修复情况。使用了7只雄性兔子。每只动物在左胫骨植入3个多孔表面植入物,在右胫骨植入3个粗糙表面植入物。术后4周处死兔子,将含有植入物的胫骨片段进行组织学和组织形态计量学分析,以评估植入物-骨界面处的新骨形成情况。在5%显著性水平下,通过配对样本的学生t检验比较组织形态计量学分析中获得的骨新形成平均值(%)。组织学分析结果表明,两种类型的植入物均发生了骨整合,骨组织质量相似。组织形态计量学分析显示,多孔表面植入物和粗糙表面植入物在植入物-骨界面处的新骨形成平均值分别为79.69±1.00%和65.05±1.23%。在新骨形成量方面,两种类型的植入物之间观察到统计学上的显著差异(p<0.05)。总之,多孔表面植入物有助于骨整合,因为它们在植入物-骨界面提供了更大的接触面积。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7483/4327200/f131bcd99da6/1678-7757-jaos-14-03-0213-gf01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验