使用三种清洁溶液后眼部假体生物膜及无眼球眼眶污染情况的评估

Evaluation of ocular prosthesis biofilm and anophthalmic cavity contamination after use of three cleansing solutions.

作者信息

Paranhos Regina Márcia Zuccolotto Felippe, Batalhão Carlos Henrique, Semprini Marisa, Regalo Simone Cecílio Hallak, Ito Izabel Yoko, de Mattos Maria da Glória Chiarello

机构信息

Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil.

出版信息

J Appl Oral Sci. 2007 Feb;15(1):33-8. doi: 10.1590/s1678-77572007000100008.

Abstract

UNLABELLED

In addition to an initial socket discomfort, ocular prosthesis (OP) installation may allow the adherence of fungi and/or bacteria due to the superficial characteristics of the prosthesis' material, use of inadequate cleansing solutions and methods, or because the void located between the internal portion of the prosthesis and the anophthalmic cavity (AC) mucosa.

OBJECTIVE

The aim of this study was to evaluate OP biofilm formation and the level of contamination of the internal portion of the OP and the AC in 24 patients.

MATERIAL AND METHODS

Material was collected from the AC at the beginning of the study and 15 days after cleansing of the OP with 3 cleansing solutions: a neutral liquid soap, a multiuse solution for contact lens (Complete) and 0.12% chlorhexidine (Periogard). The collected materials were sowed in Petri dishes containing selective media for aerobic and facultative microorganisms, specifically staphylococci (Hipersalt agar with egg yolk), aerobic microorganisms (Brain Heart Infusion Blood Agar), streptococci (Mitis salivarius Agar), gram-negative bacilli (MacConkey Agar) and yeasts (Chromagar Candida), incubated at 35 degrees C or 37 degrees C and the number of colony forming units were counted. Data were analyzed statistically by ANOVA, Friedman's test and Spearman's correlation.

RESULTS

Aerobic microorganisms, gram-negative bacilli and S. aureus were found in the OP biofilm and in the AC. There was statistically significant difference (p<0.05) between the number of microorganisms before and after the use of the cleansing solutions.

CONCLUSION

There was positive correlation with respect to the microorganisms present in the OP biofilm and AC for the 4 proposed treatments, indicating that the decrease of OP contamination leads to AC contamination as well.

摘要

未标注

除了最初的眼窝不适外,由于义眼(OP)材料的表面特性、清洁溶液和方法使用不当,或者由于义眼内部与无眼球眼眶(AC)黏膜之间存在空隙,义眼安装可能会使真菌和/或细菌附着。

目的

本研究旨在评估24例患者的义眼生物膜形成情况以及义眼内部和无眼球眼眶的污染程度。

材料与方法

在研究开始时以及用3种清洁溶液清洁义眼15天后,从无眼球眼眶收集材料,这3种清洁溶液分别为:中性液体肥皂、隐形眼镜多用护理液(Complete)和0.12%洗必泰(Periogard)。将收集的材料接种在含有需氧和兼性微生物选择性培养基的培养皿中,具体为葡萄球菌(含蛋黄的高盐琼脂)、需氧微生物(脑心浸液血琼脂)、链球菌(唾液链球菌琼脂)、革兰氏阴性杆菌(麦康凯琼脂)和酵母菌(念珠菌显色琼脂),在35℃或37℃下培养并计算菌落形成单位数量。数据采用方差分析、弗里德曼检验和斯皮尔曼相关性分析进行统计学分析。

结果

在义眼生物膜和无眼球眼眶中发现了需氧微生物、革兰氏阴性杆菌和金黄色葡萄球菌。使用清洁溶液前后微生物数量存在统计学显著差异(p<0.05)。

结论

对于4种提议的治疗方法,义眼生物膜和无眼球眼眶中存在的微生物呈正相关,表明义眼污染的减少也会导致无眼球眼眶污染。

相似文献

引用本文的文献

5
Cryolite glass prosthetic eyes-the response of the anophthalmic socket.冰晶石玻璃义眼——无眼球眼眶的反应
Graefes Arch Clin Exp Ophthalmol. 2019 Sep;257(9):2015-2023. doi: 10.1007/s00417-019-04395-y. Epub 2019 Jun 15.

本文引用的文献

6
A detergent-lubricant solution for artificial eyes.一种用于人工眼的去污剂-润滑剂溶液。
Am J Ophthalmol. 1966 Jun;61(6):1502-5. doi: 10.1016/0002-9394(66)90492-2.
7
A study of ocular prostheses. I. Manufacture and indications for use.
Rev Fac Odontol Ribeiro Preto. 1986 Jul-Dec;23(2):135-43.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验