León L P, Sansur M, Snyder L R, Horvath C
Clin Chem. 1977 Sep;23(9):1556-62.
Small-bore ("Autozyme") tubes with immobilized enzymes at the inner wall have been developed and studied for application in the Technicon "SMAC" high-speed continuous-flow biochemical analyzer. Tubes coated with glucose oxidase (D-glucose:oxygen oxidoreductase, EC 1.1.3.4) have been prepared for the assay of glucose, with colorimetric assay of the hydrogen peroxide produced; tubes coated with glycerol kinase (ATP:glycerol phosphotransferase, EC 2.7.1.30) for the enzymatic assay of triglycerides; tubes coated with hexokinase (ATP:D-hexose-6-phosphotransferase, EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (D-glucose-6-phosphate:NAD+ oxidoreductase EC 1.1.1.49) for the measurement of ATP, an intermediate product in assays for creatine kinase. With use of 10-15 cm lengths of Autozyme tube and SMAC hydraulics (150 samples per hour), assay sensitivity and carryover were similar to values for the corresponding free-enzyme methods. These immobilized enzymes were sufficiently stable for one to eight weeks of continuous use before replacemnt. We conclude that suitable bound-enzyme tubes can replace either single or multiple free-enzyme reagents in many continuous-flow assays at high sampling rates.
内壁固定有酶的小口径(“自动酶”)管已被开发并用于Technicon“SMAC”高速连续流动生化分析仪。已制备涂有葡萄糖氧化酶(D-葡萄糖:氧氧化还原酶,EC 1.1.3.4)的管用于葡萄糖测定,通过比色法测定产生的过氧化氢;涂有甘油激酶(ATP:甘油磷酸转移酶,EC 2.7.1.30)的管用于甘油三酯的酶促测定;涂有己糖激酶(ATP:D-己糖-6-磷酸转移酶,EC 2.7.1.1)和葡萄糖-6-磷酸脱氢酶(D-葡萄糖-6-磷酸:NAD +氧化还原酶EC 1.1.1.49)的管用于测量ATP,这是肌酸激酶测定中的中间产物。使用10 - 15厘米长的自动酶管和SMAC液压系统(每小时150个样本),测定灵敏度和残留量与相应的游离酶方法的值相似。这些固定化酶在更换前连续使用一至八周足够稳定。我们得出结论,在许多高采样率的连续流动测定中,合适的固定化酶管可以替代单一或多种游离酶试剂。