Wolffsohn James S, Hunt Olivia A, Basra Amritpreet K
Ophthalmic Research Group, Life and Health Sciences, Aston University, Aston Triangle, Birmingham, UK.
Cont Lens Anterior Eye. 2009 Feb;32(1):37-42. doi: 10.1016/j.clae.2008.12.004. Epub 2009 Jan 22.
To determine the critical fitting characteristics of modern soft contact lens fits and from this to devise a simplified recording scheme.
Ten subjects (aged 28.1+/-7.4 years) wore eight different modern soft contact lenses. Video was captured and analysed of blink (central and up-gaze), excursion lag (up, down, right and left gaze) and push-up movement, centration and coverage.
Lens centration was on average close to the corneal centre. Movement on blink was significantly smaller in up-gaze than in primary-gaze (p<0.001). Lag was greatest in down-gaze and least in up-gaze (p<0.001). Push-up test recovery speed was 1.32+/-0.73 mm/s. Overall lens movement was determined best by assessing horizontal lag, movement on blink in up-gaze and push-up recovery speed. Steeper lens base-curves did not have a significant effect on lens fit characteristics. Contact lens material did influence lens fit characteristics, particularly silicone-hydrogels which generally had lower centration and a faster push-up speed of recovery than HEMA lenses (p<0.05).
Lag on vertical gaze, and movement on blink in primary gaze generally provide little extra information on overall lens movement compared to horizontal lag, movement on blink in up-gaze and push-up recovery speed. They can therefore be excluded from a simplified recording scheme. A simplified and comprehensive soft contact lens fit recording system could consist of a cross-hairs indicating the centre of the cornea; a circle to indicate the lens centration; a mark on the relevant position of the circle to indicate any limbal incursion; a grade (B) below for movement with blink in up-gaze, a grade (L) to the side for horizontal lag and a grade above (P) for the assessed push-up recovery speed.
确定现代软性接触镜适配的关键特征,并据此设计一种简化的记录方案。
10名受试者(年龄28.1±7.4岁)佩戴8种不同的现代软性接触镜。对眨眼(中央注视和向上注视)、偏移滞后(向上、向下、向右和向左注视)以及上推运动、定中心和覆盖情况进行视频采集和分析。
镜片定中心平均接近角膜中心。向上注视时眨眼的运动明显小于主注视时(p<0.001)。向下注视时滞后最大,向上注视时最小(p<0.001)。上推试验恢复速度为1.32±0.73毫米/秒。通过评估水平滞后、向上注视时眨眼的运动和上推恢复速度能最好地确定镜片的整体运动。较陡的镜片基弧对镜片适配特征没有显著影响。接触镜材料确实会影响镜片适配特征,特别是硅水凝胶,其定中心通常较低,上推恢复速度比水凝胶镜片快(p<0.05)。
与水平滞后、向上注视时眨眼的运动和上推恢复速度相比,垂直注视时的滞后以及主注视时眨眼的运动通常在镜片整体运动方面提供的额外信息很少。因此,它们可以从简化记录方案中排除。一个简化且全面的软性接触镜适配记录系统可以包括一个十字线指示角膜中心;一个圆圈指示镜片定中心;在圆圈的相关位置做一个标记以指示任何角膜缘侵入;向上注视时眨眼运动下方的等级(B),水平滞后一侧的等级(L)以及评估的上推恢复速度上方的等级(P)。