School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.
National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China.
Dis Markers. 2022 Mar 18;2022:7220706. doi: 10.1155/2022/7220706. eCollection 2022.
This study aimed to evaluate the medium-term fit of soft contact lenses (SCLs) and its effects on dry eye by using ultra-high-resolution optical coherence tomography (UHR-OCT) and digital slit-lamp biomicroscopy (DSLB) and identify factors indicating a better contact lens fit.
A total of 14 participants (7 men, 7 women; mean age, 23.1 years) were recruited. Temporal lag and conjunctival coverage were imaged by UHR-OCT. DSLB was used to assess lens decentration and blink-induced movement. In addition, dry eye indices, including ocular surface disease index (OSDI), tear break-up time (TBUT), and Schirmer I test scores, were measured at baseline and 1 day, 1 week, 1 month, 3 months, and 6 months after wearing.
Good repeatability was found in the assessments of lens fit characteristics by two researchers and in the assessments by one researcher at different follow-up times. There were no significant differences in lens fit characteristics, TBUT and Schirmer I test scores at each checkpoint (P >0.05). However, the OSDI was significantly higher than baseline after wearing (P <0.05). Changes in the temporal lag were positively correlated with changes in TBUT (r =0.544, P =0.044) and negatively correlated with changes in OSDI (r = -0.629, P =0.016). Changes in blink-induced movement were positively correlated with changes in OSDI, Schirmer I test scores, and TBUT (P <0.05).
UHR-OCT and DSLB can be used to comprehensively and quantitatively evaluate SCL fit. Both the contact lenses and ocular surface conditions are almost stable within 6 months of SCL wear. Temporal lag and blink-induced movement have a strong correlation with dry eye parameters in SCL wearers.
本研究旨在使用超高清光学相干断层扫描(UHR-OCT)和数字式眼前节镜(DSLB)评估软性隐形眼镜(SCL)的中期适配情况及其对干眼症的影响,并确定指示更好的隐形眼镜适配的因素。
共招募 14 名参与者(7 名男性,7 名女性;平均年龄 23.1 岁)。通过 UHR-OCT 成像评估时滞和结膜覆盖度。使用 DSLB 评估镜片偏心度和眨眼引起的运动。此外,在佩戴 SCL 后第 1 天、第 1 周、第 1 个月、第 3 个月和第 6 个月测量眼表疾病指数(OSDI)、泪膜破裂时间(TBUT)和 Schirmer I 试验评分等干眼指标。
两位研究人员评估镜片适配特征的重复性较好,一位研究人员在不同随访时间的评估重复性也较好。在每个检查点,镜片适配特征、TBUT 和 Schirmer I 试验评分均无显著差异(P>0.05)。然而,佩戴后 OSDI 显著高于基线(P<0.05)。时滞的变化与 TBUT 的变化呈正相关(r=0.544,P=0.044),与 OSDI 的变化呈负相关(r=-0.629,P=0.016)。眨眼引起的运动变化与 OSDI、Schirmer I 试验评分和 TBUT 的变化呈正相关(P<0.05)。
UHR-OCT 和 DSLB 可用于全面、定量地评估 SCL 适配。佩戴 SCL 后 6 个月内,隐形眼镜和眼表状况几乎保持稳定。在 SCL 佩戴者中,时滞和眨眼引起的运动与干眼参数具有很强的相关性。