Suppr超能文献

利用谱域光学相干断层扫描对整个隐形眼镜进行体内和体外成像。

Entire contact lens imaged in vivo and in vitro with spectral domain optical coherence tomography.

机构信息

Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA.

出版信息

Eye Contact Lens. 2010 Mar;36(2):73-6. doi: 10.1097/ICL.0b013e3181d0423e.

Abstract

OBJECTIVES

To demonstrate the capability of directly visualizing the entire ocular surface and the entire contact lens on the eye using spectral domain optical coherence tomography (SD-OCT).

METHODS

A custom-built, high-speed, and high-resolution SD-OCT was developed with extended scan depth and width. The eye was imaged before and after wearing a toric soft contact lens (PureVision; Bausch & Lomb). A lubricant eye drop (Soothe; Bausch & Lomb) was instilled in the eye to enhance the image contrast on the lens. The same toric soft contact lens immersed in the contact lens solution was also imaged with a contrast enhancement medium (0.5% Intralipid).

RESULTS

Cross-sectional OCT images of the entire ocular surface were acquired with high-resolution 2,048 x 2,048 pixels. Quantitative surface height map of the ocular surface was obtained from a radial scan data set containing 32 B-scans. With the contrast enhancement agent, the entire toric soft contact lens was clearly visualized, both in vitro and on the eye. The surfaces of the lens were detected and used to generate the thickness maps of the soft contact lens.

CONCLUSIONS

Spectral domain optical coherence tomography with extended scan depth and width is a promising tool for imaging the entire ocular surface shape and soft contact lenses. This successful demonstration suggests that the extended depth SD-OCT is effective in studying ocular surface shape and its interaction with a soft contact lens. The novel method is helpful for the evaluation of contact lens fitting and lens design.

摘要

目的

展示使用谱域光学相干断层扫描(SD-OCT)直接可视化整个眼表和整个隐形眼镜的能力。

方法

开发了一种定制的、高速和高分辨率的 SD-OCT,具有扩展的扫描深度和宽度。在佩戴散光软隐形眼镜(PureVision;Bausch & Lomb)前后对眼睛进行成像。在眼睛中滴注润眼液(Soothe;Bausch & Lomb)以增强隐形眼镜上的图像对比度。还使用对比度增强介质(0.5%Intralipid)对浸泡在隐形眼镜溶液中的相同散光软隐形眼镜进行成像。

结果

使用高分辨率 2048 x 2048 像素获得了整个眼表的横截面 OCT 图像。从包含 32 个 B 扫描的径向扫描数据集获得了眼表的定量表面高度图。使用对比度增强剂,可以清楚地看到整个散光软隐形眼镜,无论是在体外还是在眼睛上。检测到镜片的表面并用于生成软隐形眼镜的厚度图。

结论

具有扩展扫描深度和宽度的谱域光学相干断层扫描是一种很有前途的成像整个眼表形状和软隐形眼镜的工具。这一成功的演示表明,扩展深度 SD-OCT 可有效研究眼表形状及其与软隐形眼镜的相互作用。这种新方法有助于评估隐形眼镜的适配和镜片设计。

相似文献

1
Entire contact lens imaged in vivo and in vitro with spectral domain optical coherence tomography.
Eye Contact Lens. 2010 Mar;36(2):73-6. doi: 10.1097/ICL.0b013e3181d0423e.
2
In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography.
Eye Contact Lens. 2009 Mar;35(2):44-9. doi: 10.1097/ICL.0b013e31819579f2.
4
Optical Assessment of Soft Contact Lens Edge-Thickness.
Optom Vis Sci. 2016 Aug;93(8):987-96. doi: 10.1097/OPX.0000000000000892.
5
Micrometer-scale contact lens movements imaged by ultrahigh-resolution optical coherence tomography.
Am J Ophthalmol. 2012 Feb;153(2):275-283.e1. doi: 10.1016/j.ajo.2011.06.023. Epub 2011 Sep 13.
6
OCT applications in contact lens fitting.
Cont Lens Anterior Eye. 2022 Aug;45(4):101540. doi: 10.1016/j.clae.2021.101540. Epub 2021 Nov 17.
8
The effect of contact lens wear on retinal spectral domain optical coherence tomography.
Clin Exp Optom. 2020 Nov;103(6):792-797. doi: 10.1111/cxo.13064. Epub 2020 Mar 30.
9
Effect of contact lens on optical coherence tomography imaging of rodent retina.
Curr Eye Res. 2013 Dec;38(12):1235-40. doi: 10.3109/02713683.2013.815218. Epub 2013 Sep 3.
10
Extended scan depth optical coherence tomography for evaluating ocular surface shape.
J Biomed Opt. 2011 May;16(5):056007. doi: 10.1117/1.3578461.

引用本文的文献

1
Change in the geometry of positive- and negative-powered soft contact lenses during wear.
PLoS One. 2020 Nov 9;15(11):e0242095. doi: 10.1371/journal.pone.0242095. eCollection 2020.
4
Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography.
J Ophthalmol. 2017;2017:5763172. doi: 10.1155/2017/5763172. Epub 2017 Jun 1.
5
Optical Assessment of Soft Contact Lens Edge-Thickness.
Optom Vis Sci. 2016 Aug;93(8):987-96. doi: 10.1097/OPX.0000000000000892.
6
An Optical Section-Assisted In Vivo Rabbit Model for Capsular Bend and Posterior Capsule Opacification Investigation.
PLoS One. 2016 Feb 3;11(2):e0148553. doi: 10.1371/journal.pone.0148553. eCollection 2016.
9

本文引用的文献

3
In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography.
Eye Contact Lens. 2009 Mar;35(2):44-9. doi: 10.1097/ICL.0b013e31819579f2.
4
Simplified recording of soft contact lens fit.
Cont Lens Anterior Eye. 2009 Feb;32(1):37-42. doi: 10.1016/j.clae.2008.12.004. Epub 2009 Jan 22.
5
Spectral optical coherence tomography in video-rate and 3D imaging of contact lens wear.
Optom Vis Sci. 2007 Dec;84(12):1104-9. doi: 10.1097/OPX.0b013e31815b9e0e.
6
Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography.
Invest Ophthalmol Vis Sci. 2007 Dec;48(12):5499-504. doi: 10.1167/iovs.07-0591.
7
Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.
Invest Ophthalmol Vis Sci. 2006 Aug;47(8):3325-9. doi: 10.1167/iovs.06-0055.
8
Corneal pachymetry mapping with high-speed optical coherence tomography.
Ophthalmology. 2006 May;113(5):792-9.e2. doi: 10.1016/j.ophtha.2006.01.048.
9
The topography of the central and peripheral cornea.
Invest Ophthalmol Vis Sci. 2006 Apr;47(4):1404-15. doi: 10.1167/iovs.05-1181.
10
Spectral optical coherence tomography: a new imaging technique in contact lens practice.
Ophthalmic Physiol Opt. 2006 Mar;26(2):127-32. doi: 10.1111/j.1475-1313.2006.00371.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验