Suppr超能文献

第一代和第二代硅水凝胶隐形眼镜在日常佩戴中引起的角膜形状变化。

Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear.

作者信息

Alba-Bueno Francisco, Beltran-Masgoret Angel, Sanjuan Cristian, Biarnés Marc, Marín Jesús

机构信息

EUOOT, Escola Universitària d'Optica i Optometria de Terrassa, Terrassa (Barcelona), Spain.

出版信息

Cont Lens Anterior Eye. 2009 Apr;32(2):88-92. doi: 10.1016/j.clae.2008.11.002. Epub 2009 Feb 1.

Abstract

PURPOSE

To compare the corneal topographical changes induced by two first and second generation silicone-hydrogel (SiH) contact lenses after 3 months of daily wear (DW).

METHODS

Prospective, consecutive case-series in which patients wore one of 3 different contact lenses (either the first generation SiH Focus Night & Day, the second generation SiH Acuvue Oasys or the monthly disposable Soflens 38 hydrogel lens as control group) on a DW basis for 3 months. Over-refraction, visual acuity, mean keratometry, corneal astigmatism, corneal eccentricity, superficial regularity and superficial asymmetry indices were monitored over the 3-month period.

RESULTS

Nineteen eyes of 10 patients completed the study. Seven Focus Night & Day, 7 Acuvue Oasys and 5 Soflens 38 contact lenses were fitted. There were no significant changes between any of the parameters measured at the 3-month visit in any of the SiH groups (non-parametric Wilcoxon test, p>0.05). However, the control group (Soflens 38) showed statistically significant changes regarding mean keratometry, corneal astigmatism and corneal eccentricity (p<0.05). Three patients wearing the first generation SiH showed adverse events of different degree related to their high modulus of elasticity.

CONCLUSIONS

After 3 months of DW, wearers of first and second generation SiH lenses showed greater corneal stability than hydrogel monthly disposable contact lenses users regarding commonly used topographic corneal shape indices. However, complications related to the mechanical properties of first generation SiH were seen in three patients in the follow-up time.

摘要

目的

比较第一代和第二代硅水凝胶(SiH)隐形眼镜每日佩戴(DW)3个月后引起的角膜地形图变化。

方法

前瞻性、连续病例系列研究,患者每日佩戴3种不同隐形眼镜中的一种(第一代SiH夜戴型焦点镜片、第二代SiH安视优欧舒适镜片或作为对照组的月抛型 Soflens 38水凝胶镜片),持续3个月。在3个月期间监测过矫、视力、平均角膜曲率、角膜散光、角膜偏心度、表面规则性和表面不对称指数。

结果

10例患者的19只眼完成了研究。共佩戴了7只夜戴型焦点镜片、7只安视优欧舒适镜片和5只Soflens 38隐形眼镜。在任何一个SiH组中,3个月随访时测量的任何参数之间均无显著变化(非参数威尔科克森检验,p>0.05)。然而,对照组(Soflens 38)在平均角膜曲率、角膜散光和角膜偏心度方面显示出统计学上的显著变化(p<0.05)。3名佩戴第一代SiH的患者出现了与其高弹性模量相关的不同程度的不良事件。

结论

每日佩戴3个月后,就常用的角膜地形图形状指数而言,第一代和第二代SiH镜片佩戴者比月抛型水凝胶隐形眼镜使用者表现出更高的角膜稳定性。然而,在随访期间,3名患者出现了与第一代SiH机械性能相关的并发症。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验