Blood pressure, heart rate, oxygen uptake, cardiac output, and the surface electromyogram from key muscle groups in the upper body were measured in four subjects with paraplegia during ambulation using only a reciprocating-gait orthosis (RGO) and using an RGO with movement assisted by functional electrical stimulation (FES) of the hamstring and gluteus maximus muscles. These data were compared to data collected on four able-bodied control subjects during ambulation at matched speeds. Whether walking with FES and RGOs or walking with RGOs alone, subjects had an optimum gait speed at which efficiency was highest. For paralyzed subjects using FES, the optimum walking speed was approximately 1.5 mph (2.4km/hr); without FES, the optimum speed averaged about 0.75mph (1.2km/hr). Blood pressure, heart rate, oxygen uptake, and cardiac output were measured during ambulation with FES and were found to be higher than those of controls, but they were significantly lower than those in the paralyzed subjects in RGOs with no FES. Electromyogram studies showed that the activity in upper body muscles was much higher when walking in RGOs without FES than in RGOs with FES.
在四名截瘫患者行走过程中,仅使用往复式步态矫形器(RGO)以及使用由腘绳肌和臀大肌功能性电刺激(FES)辅助运动的RGO时,测量了他们的血压、心率、摄氧量、心输出量以及上半身关键肌肉群的表面肌电图。将这些数据与四名健全对照受试者在匹配速度行走过程中收集的数据进行比较。无论是使用FES和RGO行走还是仅使用RGO行走,受试者都有一个效率最高的最佳步态速度。对于使用FES的瘫痪受试者,最佳步行速度约为每小时1.5英里(2.4公里/小时);不使用FES时,最佳速度平均约为每小时0.75英里(1.2公里/小时)。在使用FES行走过程中测量的血压、心率、摄氧量和心输出量高于对照组,但显著低于未使用FES的RGO瘫痪受试者。肌电图研究表明,不使用FES在RGO中行走时上半身肌肉的活动比使用FES在RGO中行走时高得多。