Suppr超能文献

猪小肠黏膜下层异体食管置换术失败。

Unsuccessful alloplastic esophageal replacement with porcine small intestinal submucosa.

作者信息

Doede Thorsten, Bondartschuk Michail, Joerck Carsten, Schulze Eberhard, Goernig Matthias

机构信息

Department of Pediatric Surgery, University Hospital of Jena, Jena, Germany.

出版信息

Artif Organs. 2009 Apr;33(4):328-33. doi: 10.1111/j.1525-1594.2009.00727.x.

Abstract

In general, there is no perfect method for esophageal replacement under consideration of the numerous associated risks and complications. The aim of this study was to examine a new material--small intestinal submucosa (SIS)--in alloplastic esophageal replacement. We implanted tubular SIS prosthesis about 4 cm in length in the cervical esophagus of 14 piglets (weight 9-13 kg). For the first 10 days, the animals were fed parenterally, supplemented by free given water, followed by an oral feeding phase. Four weeks after surgery, the animals were sacrificed. Only 1 of the 14 animals survived the study period of 4 weeks. The other piglets had to be sacrificed prematurely because of severe esophageal stenosis. On postmortem exploration, the prosthesis could not be found either macroscopically or histologically. Sutures between the prosthesis and the cervical muscles did not improve the results. Until now, the use of alloplastic materials in esophageal replacement has failed irrespective of the kind of material. As well as in our experiments, severe stenosis had been reported in several animal studies. The reasons for this unacceptable high rate of stenosis after alloplastic esophageal replacement seem to be multifactorial. Possible solutions could be transanastomotic splints, less inert materials, the decrease of anastomotic tension by stay sutures, the use of adult stem cells, and tissue engineering.

摘要

一般来说,考虑到众多相关风险和并发症,目前尚无完美的食管替代方法。本研究的目的是在异体食管替代中研究一种新材料——小肠黏膜下层(SIS)。我们在14只仔猪(体重9 - 13千克)的颈段食管植入了长度约4厘米的管状SIS假体。在最初的10天里,动物通过胃肠外营养喂养,并自由饮水,随后进入经口喂养阶段。手术后4周,处死动物。14只动物中只有1只存活至4周的研究期结束。其他仔猪因严重食管狭窄不得不提前处死。在尸检时,无论是宏观还是组织学检查均未发现假体。假体与颈段肌肉之间的缝合并未改善结果。到目前为止,无论使用何种材料,异体材料在食管替代中的应用均告失败。与我们的实验一样,在一些动物研究中也报道了严重狭窄。异体食管替代后这种不可接受的高狭窄率的原因似乎是多因素的。可能的解决方法包括经吻合口放置支撑物、使用惰性较小的材料、通过留置缝线降低吻合口张力、使用成体干细胞以及组织工程。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验