Suppr超能文献

经肺温度稀释法作为测量麻醉猫心输出量方法的评估。

Evaluation of transpulmonary thermodilution as a method to measure cardiac output in anesthetized cats.

作者信息

Beaulieu Kim E, Kerr Carolyn L, McDonell Wayne N

机构信息

Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada.

出版信息

Can J Vet Res. 2009 Jan;73(1):1-6.

Abstract

The objectives of this study were to evaluate the use of a transpulmonary thermodilution (Trans) technique for the measurement of cardiac output, and to determine the agreement between Trans and conventional thermodilution (TD) in anesthetized cats. Using each technique, cardiac output was measured in 5 mature cats (weights 2.4 to 5.6 kg) anesthetized with isoflurane. To induce different levels of cardiac output in each cat, anesthesia was maintained at > 1.5x end-tidal minimum alveolar concentration (MAC) of isoflurane, and at 1.3x end-tidal isoflurane MAC with and without administration of dobutamine. At least 2 comparisons between TD and Trans values were made at each cardiac output rate. Thirty-two of the 42 recorded comparisons were analyzed. Linear regression analysis (TD vs Trans) yielded an r(2) value of 0.83. The mean bias (TD-Trans) was -3.7 mL/kg/min with limits of agreement of -35.9 to 28.5 mL/kg/min. The concordance coefficient was 0.91. The Trans method showed good relationship and good agreement with TD in anesthetized cats. The Trans method is a relatively noninvasive, practical, and safe method to measure cardiac output in anesthetized cats.

摘要

本研究的目的是评估经肺热稀释(Trans)技术用于测量心输出量的情况,并确定在麻醉猫中Trans与传统热稀释(TD)之间的一致性。使用每种技术,对5只吸入异氟烷麻醉的成年猫(体重2.4至5.6千克)的心输出量进行测量。为了在每只猫中诱导不同水平的心输出量,麻醉维持在异氟烷呼气末最低肺泡浓度(MAC)的> 1.5倍,以及在给予和不给予多巴酚丁胺的情况下维持在1.3倍呼气末异氟烷MAC。在每个心输出量速率下,至少对TD和Trans值进行2次比较。对记录的42次比较中的32次进行了分析。线性回归分析(TD与Trans)得出r(2)值为0.83。平均偏差(TD - Trans)为 -3.7 mL/kg/min,一致性界限为 -35.9至28.5 mL/kg/min。一致性系数为0.91。在麻醉猫中,Trans方法与TD显示出良好的关系和良好的一致性。Trans方法是一种相对无创、实用且安全的测量麻醉猫心输出量的方法。

相似文献

引用本文的文献

本文引用的文献

5
Pulmonary artery blood temperature and the measurement of cardiac output by thermodilution.
Anaesthesia. 2002 Jun;57(6):562-6. doi: 10.1046/j.1365-2044.2002.02513.x.
10
Measuring agreement in method comparison studies.方法比较研究中的一致性测量
Stat Methods Med Res. 1999 Jun;8(2):135-60. doi: 10.1177/096228029900800204.