PURPOSE

Apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (DWI) may be of value in discriminating malignant from non-malignant lymph nodes, provided that they are reproducible. The aim of this study was to determine the inter- and intra-observer reproducibilities of ADC measurements of lymph nodes and to provide an overview of the current literature on ADC measurements in the characterization of lymph nodes.

MATERIALS AND METHODS

Twenty healthy volunteers underwent DWI of the head and neck region and the pelvic region, at b-values of 0 and 1000 s/mm(2). Two observers independently and blindly measured ADCs of lymph nodes. Inter- and intra-observer reproducibilities were assessed using the Bland-Altman method.

RESULTS

Mean ADCs of normal lymph nodes (in 10(-3)mm(2)/s) varied between 1.15 and 1.18. Ranges of mean ADC difference+/-limits of agreement (in 10(-3)mm(2)/s) for inter-observer agreement were -0.03 to 0.02+/-0.15 to 0.31. Ranges of mean ADC difference+/-limits of agreement (in 10(-3)mm(2)/s) for intra-observer agreement were 0.00 to 0.04+/-0.13 to 0.32.

CONCLUSION

In conclusion, in light of previously reported data, the results of the present study suggest that ADC measurements may not always be sufficiently reproducible to discriminate malignant from non-malignant lymph nodes. Future studies which directly compare the ADCs of different nodal pathologies/conditions are required to further investigate the inter- and intra-observer reproducibilities of ADC measurements of lymph nodes.

摘要

目的

在扩散加权磁共振成像(DWI)中,表观扩散系数(ADC)测量值可能有助于区分良恶性淋巴结,前提是其具有可重复性。本研究旨在确定 ADC 测量值在淋巴结中的重复性,并对目前关于 ADC 测量值在淋巴结特征描述中的文献进行综述。

材料和方法

20 名健康志愿者接受了头部和颈部区域以及骨盆区域的 DWI,b 值分别为 0 和 1000 s/mm²。两名观察者独立且盲法测量了淋巴结的 ADC 值。采用 Bland-Altman 法评估观察者间和观察者内的可重复性。

结果

正常淋巴结的平均 ADC 值(10⁻³mm²/s)在 1.15 到 1.18 之间。观察者间一致性的平均 ADC 差值+/-一致性界限(10⁻³mm²/s)范围为-0.03 到 0.02+/-0.15 到 0.31。观察者内一致性的平均 ADC 差值+/-一致性界限(10⁻³mm²/s)范围为 0.00 到 0.04+/-0.13 到 0.32。

结论

综上所述,根据先前报道的数据,本研究结果表明,ADC 测量值可能并不总是具有足够的可重复性,无法区分良恶性淋巴结。需要进一步进行直接比较不同淋巴结病理/状况的 ADC 值的研究,以进一步探讨淋巴结 ADC 测量值的观察者间和观察者内的可重复性。