Suppr超能文献

由于人绒毛膜促性腺激素β核心片段过量,即时检验定性人绒毛膜促性腺激素(hCG)检测设备出现假阴性结果。

False-negative results in point-of-care qualitative human chorionic gonadotropin (hCG) devices due to excess hCGbeta core fragment.

作者信息

Gronowski Ann M, Cervinski Mark, Stenman Ulf-Håkan, Woodworth Alison, Ashby Lori, Scott Mitchell G

机构信息

Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO 63110, USA.

出版信息

Clin Chem. 2009 Jul;55(7):1389-94. doi: 10.1373/clinchem.2008.121210. Epub 2009 Apr 24.

Abstract

BACKGROUND

During pregnancy, human chorionic gonadotropin (hCG) immunoreactivity in urine consists of intact hCG as well as a number of hCG variants including the core fragment of hCGbeta (hCGbeta cf). We identified 3 urine specimens with apparent false-negative results using the OSOM(R) hCG Combo Test (Genzyme Diagnostics) qualitative hCG device and sought to determine whether an excess of 1 of the fragments or variants might be the cause of the interference.

METHODS

We measured concentrations of hCG variants in the urine from 3 patients with apparent false-negative hCG results. Purified hCG variants were added to urines positive for hCG and tested using the OSOM, ICON(R) 25 hCG (Beckman Coulter), and hCG Combo SP(R) Brand (Cardinal Health) devices.

RESULTS

Dilution of these 3 urine samples resulted in positive results on the OSOM device. Quantification of hCG variants in each of the 3 patient urine specimens demonstrated that hCGbeta cf occurred in molar excess of intact hCG. Addition of purified hCGbeta cf to hCG-positive urines caused false-negative hCG results using the OSOM and ICON qualitative urine hCG devices.

CONCLUSIONS

Increased concentrations of hCGbeta cf can cause false-negative results on the OSOM and ICON qualitative urine hCG devices.

摘要

背景

在孕期,尿液中的人绒毛膜促性腺激素(hCG)免疫反应性包括完整的hCG以及许多hCG变体,其中包括hCGβ的核心片段(hCGβ cf)。我们使用OSOM® hCG组合检测(健赞诊断公司)定性hCG检测装置,鉴定出3份尿液标本出现明显的假阴性结果,并试图确定是否其中一种片段或变体过量可能是干扰的原因。

方法

我们测量了3例hCG结果明显为假阴性的患者尿液中hCG变体的浓度。将纯化的hCG变体添加到hCG阳性的尿液中,并使用OSOM、ICON® 25 hCG(贝克曼库尔特公司)和hCG组合SP®品牌(红衣主教健康公司)检测装置进行检测。

结果

这3份尿液样本稀释后,OSOM检测装置显示为阳性结果。对3例患者尿液标本中hCG变体的定量分析表明,hCGβ cf的摩尔数超过完整hCG。将纯化的hCGβ cf添加到hCG阳性尿液中,使用OSOM和ICON定性尿液hCG检测装置会导致hCG出现假阴性结果。

结论

hCGβ cf浓度升高可导致OSOM和ICON定性尿液hCG检测装置出现假阴性结果。