Singapore National Eye Centre, Singapore.
Invest Ophthalmol Vis Sci. 2010 Feb;51(2):631-6. doi: 10.1167/iovs.09-3614. Epub 2009 Jul 30.
To establish the normal measurements of diameter and cross-sectional area of the Chinese extraocular muscles (EOMs) and optic nerve-sheath complex (ON) as seen on high-field (3-Tesla; 3T) magnetic resonance imaging (MRI).
Coronal 3T MRI of the orbit (TR, 700 ms; TE, 15 ms; FOV, 160 mm; matrix, 256 x 256; slice thickness, 1 mm; and slice gap, 0) was performed on 80 normal Chinese volunteers. T1-weighted images were analyzed with computer-assisted segmentation. The diameter and the cross-sectional area of EOMs and the ON were measured from the image plane at the posterior aspect of the globe and at 7 mm behind the globe. The maximum diameter of EOM was measured from their respective reconstructed images.
The normal measurement (mean +/- SD) of diameter at the posterior aspect of the globe: medial rectus (MR), 3.6 +/- 0.4 mm; inferior rectus (IR), 3.7 +/- 0.8 mm; lateral rectus (LR), 2.3 +/- 0.5 mm; superior oblique (SO), 2.4 +/- 0.6 mm; and the ON, 5.4 +/- 0.7 mm. The normal measurement of diameter 7 mm behind the globe: MR, 3.2 +/- 0.6 mm; IR, 3.9 +/- 0.8 mm; LR, 4.0 +/- 0.8 mm; SO, 2.2 +/- 0.7 mm; and ON, 4.2 +/- 0.5 mm. The normal measurement of cross-sectional area at the posterior aspect of the globe: superior muscle group (SMG), 28.2 +/- 6.5 mm(2); MR, 25.5 +/- 3.2 mm(2); IR, 26.9 +/- 7.2 mm(2); LR, 17.3 +/- 3.9 mm(2); SO, 10.5 +/- 3.5 mm(2); and ON, 27.6 +/- 6.1 mm(2). The normal measurement of cross-sectional area 7 mm behind the globe: SMG, 24.1 +/- 6.6 mm(2); MR, 19.1 +/- 4.6 mm(2); IR, 29.5 +/- 6.6 mm(2); LR, 32.3 +/- 6.5 mm(2); SO, 9.7 +/- 3.9 mm(2); and ON, 17.1 +/- 2.9 mm(2). The normal measurement of maximum diameter: SMG, 4.8 +/- 1.1 mm; MR, 5.1 +/- 0.9 mm; IR, 5.4 +/- 1.0 mm; and LR, 4.5 +/- 0.9 mm.
The Chinese 3T MRI EOMs and ON normative data may be useful in determining pathologic enlargement of the EOMs and ON in various orbital conditions. (ClinicalTrials.gov number, NCT00348413.).
建立中国人眼外肌(EOM)和视神经鞘复合体(ON)在高场(3 特斯拉;3T)磁共振成像(MRI)上的正常直径和横截面积测量值。
对 80 名正常中国志愿者进行眼眶冠状位 3T MRI(TR,700 ms;TE,15 ms;视野,160 mm;矩阵,256 x 256;层厚,1 mm;层间距,0)。使用计算机辅助分割分析 T1 加权图像。在眼球后侧面和眼球后 7mm 处的图像平面上测量 EOM 和 ON 的直径和横截面积。EOM 的最大直径从各自的重建图像中测量。
眼球后侧面的正常测量值(平均值 +/- SD):内直肌(MR),3.6 +/- 0.4 毫米;下直肌(IR),3.7 +/- 0.8 毫米;外直肌(LR),2.3 +/- 0.5 毫米;上斜肌(SO),2.4 +/- 0.6 毫米;视神经,5.4 +/- 0.7 毫米。眼球后 7mm 处的正常测量值:MR,3.2 +/- 0.6 毫米;IR,3.9 +/- 0.8 毫米;LR,4.0 +/- 0.8 毫米;SO,2.2 +/- 0.7 毫米;视神经,4.2 +/- 0.5 毫米。眼球后侧面的正常横截面积测量值:上直肌群(SMG),28.2 +/- 6.5 平方毫米;MR,25.5 +/- 3.2 平方毫米;IR,26.9 +/- 7.2 平方毫米;LR,17.3 +/- 3.9 平方毫米;SO,10.5 +/- 3.5 平方毫米;视神经,27.6 +/- 6.1 平方毫米。眼球后 7mm 处的正常横截面积测量值:SMG,24.1 +/- 6.6 平方毫米;MR,19.1 +/- 4.6 平方毫米;IR,29.5 +/- 6.6 平方毫米;LR,32.3 +/- 6.5 平方毫米;SO,9.7 +/- 3.9 平方毫米;视神经,17.1 +/- 2.9 平方毫米。最大直径的正常测量值:SMG,4.8 +/- 1.1 毫米;MR,5.1 +/- 0.9 毫米;IR,5.4 +/- 1.0 毫米;LR,4.5 +/- 0.9 毫米。
中国人 3T MRI 眼外肌和视神经鞘正常数据可用于确定各种眼眶疾病中外直肌和视神经鞘的病理性增大。(临床试验.gov 编号,NCT00348413.)