Ishihata Hiroshi, Kanehira Masafumi, Nagai Tomoko, Finger Werner J, Shimauchi Hidetoshi, Komatsu Masashi
Department of Restorative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan.
Am J Dent. 2009 Jun;22(3):143-6.
To investigate the in vitro efficacy of two dentin desensitizing products at reducing liquid permeability through human dentin discs. The tested hypothesis was that the products, in spite of different chemical mechanisms were not different at reducing or eliminating flow through dentin discs.
Dentin slices (1 mm thick) were prepared from 16 extracted human third molars and their permeability was indirectly recorded in a split chamber model, using a chemiluminescence technique, after EDTA treatment (control), after soaking with albumin, and after desensitizer application. Two products were studied: MS Coat, a self-curing resin-containing oxalate product, and Gluma Desensitizer, a glutaraldehyde/HEMA-based agent without initiator. The dentin slices were mounted between an upper chamber, filled with an aqueous solution of 1% potassium ferricyanide and 0.3% hydrogen peroxide, and a lower chamber filled with 1% sodium hydroxide solution and 0.02% luminol. The upper solution was pressurized, and upon contact with the luminol solution a photochemical signal was generated and recorded as a measure of permeability throughout two consecutive pressurizing cycles at 2.5 and 13 kPa (26 and 133 cm H2O), respectively.
The permeability of the control and albumin-soaked samples was similarly high. After application of the desensitizing agents, dentin permeability was reduced to virtually zero at both pressure levels (P < 0.001).
研究两种牙本质脱敏产品在降低通过人牙本质片的液体渗透性方面的体外效果。所测试的假设是,尽管这两种产品的化学作用机制不同,但在降低或消除通过牙本质片的液体流动方面并无差异。
从16颗拔除的人类第三磨牙制备牙本质片(1毫米厚),在乙二胺四乙酸(EDTA)处理后(对照)、白蛋白浸泡后以及应用脱敏剂后,使用化学发光技术在分隔腔模型中间接记录其渗透性。研究了两种产品:MS Coat,一种含草酸盐的自固化树脂产品;以及Gluma脱敏剂,一种不含引发剂的基于戊二醛/甲基丙烯酸羟乙酯(HEMA)的制剂。将牙本质片安装在一个上腔室和一个下腔室之间,上腔室装有1%铁氰化钾水溶液和0.3%过氧化氢,下腔室装有1%氢氧化钠溶液和0.02%鲁米诺。对上腔室溶液施加压力,当与鲁米诺溶液接触时会产生光化学信号,并在分别为2.5和13千帕(26和133厘米水柱)的两个连续加压周期中记录该信号作为渗透性的度量。
对照和白蛋白浸泡样本的渗透性同样高。应用脱敏剂后,在两个压力水平下牙本质渗透性均降至几乎为零(P < 0.001)。