Suppr超能文献

成人和青少年活动问卷(AQuAA)的信度和效度。

Reliability and validity of the Activity Questionnaire for Adults and Adolescents (AQuAA).

机构信息

EMGO-Institute for Health and Care research, Department of Public and Occupational Health, VU University Medical Center, 1081 BT Amsterdam, The Netherlands.

出版信息

BMC Med Res Methodol. 2009 Aug 10;9:58. doi: 10.1186/1471-2288-9-58.

Abstract

BACKGROUND

Accurate measures of physical activity are highly needed. We evaluated the test-retest reliability and construct validity of the self-report Activity Questionnaire for Adults and Adolescents (AQuAA). The AQuAA is a commonly used questionnaire in Dutch youth.

METHODS

In the test-retest reliability study, 53 adolescents and 58 adults completed the AQuAA twice, with an interval of two weeks. In the validity study, 33 adolescents and 47 adults wore an accelerometer (Actigraph) during two weeks, and subsequently completed the AQuAA.

RESULTS

In adolescents the test-retest reliability was fair to moderate (intraclass correlations (ICCs) ranging from 0.30 to 0.59). In adults the test-retest reliability was fair to moderate for the time spent on sedentary, light and moderate intensity activities (ICCs ranging from 0.49 to 0.60), but poor for time spent on vigorous activities (ICC = -0.005). The correlations between the AQuAA and Actigraph were low and nonsignificant. Compared with the Actigraph, time spent on all physical activities was significantly higher according to the questionnaire (except for light intensity activities in adolescents), while time spent on sedentary behaviours was significantly lower.

CONCLUSION

Reliability of the AQuAA is fair to moderate. The validity of the AQuAA compared to an accelerometer is poor. Both adolescents and adults underestimate the time spent on sedentary behaviours and overestimate the time spent on physical activities.

摘要

背景

准确的身体活动测量非常重要。我们评估了成人和青少年活动问卷(AQuAA)的重测信度和结构效度。AQuAA 是荷兰青少年常用的问卷。

方法

在重测信度研究中,53 名青少年和 58 名成年人在两周内两次完成 AQuAA。在有效性研究中,33 名青少年和 47 名成年人在两周内佩戴加速度计(Actigraph),随后完成 AQuAA。

结果

在青少年中,重测信度为中等到适度(组内相关系数(ICCs)范围为 0.30 至 0.59)。在成年人中,静坐、轻和中强度活动的时间重测信度为中等到适度(ICCs 范围为 0.49 至 0.60),但剧烈活动的时间重测信度较差(ICC = -0.005)。AQuAA 与 Actigraph 之间的相关性较低且无统计学意义。与 Actigraph 相比,根据问卷,所有身体活动的时间明显更高(青少年的轻强度活动除外),而久坐行为的时间明显更低。

结论

AQuAA 的可靠性为中等到适度。与加速度计相比,AQuAA 的有效性较差。青少年和成年人都低估了久坐行为的时间,高估了身体活动的时间。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/08a1/3224705/2869841b173d/1471-2288-9-58-1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验