Suppr超能文献

在正常人群、青光眼疑似患者和早期青光眼患者中,通过扫描激光偏振仪(GDxVCC)在常规和改良直径扫描下测量视网膜神经纤维层厚度。

Retinal nerve fiber layer thickness measurement by scanning laser polarimetry (GDxVCC) at conventional and modified diameter scans in normals, glaucoma suspects, and early glaucoma patients.

作者信息

Dada Tanuj, Gadia Ritu, Aggarwal Anand, Dave Vivek, Gupta Viney, Sihota Ramanjit

机构信息

Glaucoma Facility, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

出版信息

J Glaucoma. 2009 Aug;18(6):448-52. doi: 10.1097/IJG.0b013e3181895e2b.

Abstract

PURPOSE

To study the retinal nerve fiber layer (RNFL) at 3 different scan diameters using GDxVCC in healthy, primary open-angle glaucoma (POAG) suspects, and early POAG.

METHOD

RNFL parameters were evaluated in 100 normal subjects, 50 POAG suspects, and 50 early POAG patients using GDxVCC at conventional small, medium, and large circle. TSNIT (temporal, superior, nasal, inferior, temporal) average, superior average, inferior average RNFL thickness, and nerve fiber indicator (NFI) were evaluated.

RESULTS

The TSNIT average (microm) in normal subjects, POAG suspects, and POAG at 3 different circles was 54.17+/-4.6, 49.96+/-6.5, 46.92+/-6.2 (small); 47.17+/-4.8, 43.79+/-5.7, 41.48+/-6.5 (medium); and 41.57+/-4.6, 39.77+/-5.9, 38.33+/-7.1 (large). All RNFL parameters at all circles showed significant difference between normal and early POAG eyes (P<0.001). Area under the curve was 0.911 for NFI at all circles. All parameters at small and medium circle, all except TSNIT average at large circle showed significant difference between normal and POAG suspects (P<0.001), area under curve being the highest (0.780 to 0.801 at 3 circles) for NFI. All parameters progressively decreased with increasing diameter with significant difference between small-medium (P<0.001), medium-large (P<0.001), and small-large circle results (P<0.001) in all the groups for all parameters except NFI.

CONCLUSIONS

Medium and large circles can also be used for RNFL evaluation in glaucoma. NFI is the best discriminating measure across all scan diameters.

摘要

目的

使用GDxVCC在3种不同扫描直径下研究健康人、原发性开角型青光眼(POAG)疑似患者及早期POAG患者的视网膜神经纤维层(RNFL)。

方法

使用GDxVCC在常规小、中、大圆周对100名正常受试者、50名POAG疑似患者和50名早期POAG患者的RNFL参数进行评估。评估颞侧、上方、鼻侧、下方、颞侧(TSNIT)平均值、上方平均值、下方平均RNFL厚度及神经纤维指数(NFI)。

结果

在3种不同圆周下,正常受试者、POAG疑似患者和POAG患者的TSNIT平均值(微米)分别为:小圆周54.17±4.6、49.96±6.5、46.92±6.2;中圆周47.17±4.8、43.79±5.7、41.48±6.5;大圆周41.57±4.6、39.77±5.9、38.33±7.1。所有圆周下的所有RNFL参数在正常眼和早期POAG眼之间均显示出显著差异(P<0.001)。所有圆周下NFI的曲线下面积为0.911。小圆周和中圆周的所有参数,除大圆周的TSNIT平均值外,在正常受试者和POAG疑似患者之间均显示出显著差异(P<0.001),NFI的曲线下面积最高(3种圆周下为0.780至0.801)。除NFI外,所有组的所有参数随直径增加而逐渐降低,小-中圆周(P<0.001)、中-大圆周(P<0.001)和小-大圆周结果(P<0.001)之间存在显著差异。

结论

中圆周和大圆周也可用于青光眼的RNFL评估。NFI是所有扫描直径下最佳的鉴别指标。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验