Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.
Eur Radiol. 2010 Apr;20(4):862-9. doi: 10.1007/s00330-009-1613-1. Epub 2009 Sep 30.
To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT).
A scout dose (60 mg) was injected into the hepatic artery of five pigs and SPECT acquired. Subsequently, a 'treatment dose' was administered (540 mg) and SPECT, computed tomography (CT) and magnetic resonance imaging (MRI) of the total dose performed. The two SPECT images of each animal were compared. To validate quantitative SPECT an ex vivo liver was instilled with (166)Ho-PLLA-MS and SPECT acquired. The liver was cut into slices and planar images were acquired, which were registered to the SPECT image.
Qualitatively, the scout dose and total dose images were similar, except in one animal because of catheter displacement. Quantitative analysis, feasible in two animals, tended to confirm this similarity (r(2) = 0.34); in the other animal the relation was significantly better (r(2) = 0.66). The relation between the SPECT and planar images acquired from the ex vivo liver was strong (r(2) = 0.90).
In the porcine model a scout dose of (166)Ho-PLLA-MS can accurately predict the biodistribution of a treatment dose. Quantitative (166)Ho SPECT was validated for clinical application.
利用单光子发射断层扫描术(SPECT)评估钬-166 聚乳酸微球((166)Ho-PLLA-MS)的示踪剂量预测治疗剂量(166)Ho-PLLA-MS 分布的准确性。
将 60mg 示踪剂注入五头猪的肝动脉,采集 SPECT 图像。随后,给予“治疗剂量”(540mg),并对总剂量进行 SPECT、计算机断层扫描(CT)和磁共振成像(MRI)检查。对每个动物的两个 SPECT 图像进行比较。为了验证定量 SPECT,将(166)Ho-PLLA-MS 注入离体肝脏并采集 SPECT 图像。将肝脏切成薄片并采集平面图像,并将其与 SPECT 图像配准。
定性上,示踪剂量和总剂量图像相似,除了一只动物因导管移位而有所不同。在两只动物中进行的定量分析倾向于证实这种相似性(r(2) = 0.34);在另一只动物中,相关性更好(r(2) = 0.66)。从离体肝脏获得的 SPECT 和平面图像之间的关系很强(r(2) = 0.90)。
在猪模型中,(166)Ho-PLLA-MS 的示踪剂量可以准确预测治疗剂量的生物分布。(166)Ho SPECT 的定量分析已验证可用于临床应用。