Suppr超能文献

麻醉患者中声门上气道 I-gel 与 ProSeal 喉罩气道和经典喉罩气道的比较。

The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients.

机构信息

Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.

出版信息

Eur J Anaesthesiol. 2010 Jul;27(7):598-601. doi: 10.1097/EJA.0b013e3283340a81.

Abstract

BACKGROUND AND OBJECTIVE

The I-gel is a new single-use supraglottic airway device without an inflatable cuff. This study was designed to investigate the usefulness of the I-gel compared with the classic laryngeal mask airway (cLMA) and ProSeal laryngeal mask airway (pLMA) in anaesthetized, paralysed patients.

METHODS

The American Society of Anesthesiologists physical status I-II patients (n = 167) scheduled for orthopaedic surgery were included in this prospective study. General anaesthesia was achieved with intravenous infusion of propofol, remifentanil and rocuronium. The patients were randomly assigned to I-gel, pLMA and cLMA groups (64, 53 and 50 patients, respectively). Properly sized I-gel (No. 3-4) or LMA (No. 4-5) was inserted. We assessed haemodynamic data, airway leak pressure, leak volume, success rates and postoperative complications.

RESULTS

There were no differences in the demographic data and haemodynamic data immediately after insertion of devices among the three groups. The airway leak pressures of the I-gel group (27.1 +/- 6.4 cmH2O) and pLMA group (29.8 +/- 5.7 cmH2O) were significantly higher than that of the cLMA group (24.7 +/- 6.2 cmH2O). The success rates for first attempt of insertion were similar among the three groups (P = 0.670). There were no differences in the incidence of adverse events except for the larger incidence of sore throat in the cLMA group.

CONCLUSION

I-gel may have a similar airway sealing to that of pLMA, higher than that of cLMA, and is not associated with adverse events. The I-gel might be an effective alternative as a supraglottic airway device.

摘要

背景与目的

I-gel 是一种新型的一次性使用的声门上气道装置,没有可充气的套囊。本研究旨在比较 I-gel 与经典的喉罩气道(cLMA)和 ProSeal 喉罩气道(pLMA)在麻醉、肌松下患者中的有效性。

方法

本前瞻性研究纳入了美国麻醉医师协会(ASA)身体状况 I-II 级的择期行骨科手术患者(n=167)。全身麻醉采用异丙酚静脉输注、瑞芬太尼和罗库溴铵。患者被随机分为 I-gel 组、pLMA 组和 cLMA 组(分别为 64、53 和 50 例患者)。插入合适大小的 I-gel(No. 3-4)或 LMA(No. 4-5)。我们评估了血流动力学数据、气道漏气压、漏气量、成功率和术后并发症。

结果

三组患者在插入装置后即刻的人口统计学数据和血流动力学数据无差异。I-gel 组(27.1±6.4 cmH2O)和 pLMA 组(29.8±5.7 cmH2O)的气道漏气压明显高于 cLMA 组(24.7±6.2 cmH2O)。三组患者首次尝试插入的成功率相似(P=0.670)。除 cLMA 组咽痛发生率较高外,三组患者不良事件的发生率无差异。

结论

I-gel 可能具有与 pLMA 相似的气道密封效果,高于 cLMA,且与不良事件无关。I-gel 可能是一种有效的声门上气道装置替代物。