Almgren M, Lundmark M, Samuelson K
Department of Health Sciences, Division of Nursing, Lund University, Lund, Sweden.
Acta Anaesthesiol Scand. 2010 Jul;54(6):729-35. doi: 10.1111/j.1399-6576.2009.02173.x. Epub 2009 Dec 5.
Awareness about adequate sedation in mechanically ventilated patients has increased in recent years. The use of a sedation scale to continually evaluate the patient's response to sedation may promote earlier extubation and may subsequently have a positive effect on the length of stay in the intensive care unit (ICU). The Richmond Agitation-Sedation Scale (RASS) provides 10 well-defined levels divided into two different segments, including criteria for levels of sedation and agitation. Previous studies of the RASS have shown it to have strong reliability and validity. The aim of this study was to translate the RASS into Swedish and to test the inter-rater reliability of the scale in a Swedish ICU.
A translation of the RASS from English into Swedish was carried out, including back-translation, critical review and pilot testing. The inter-rater reliability testing was conducted in a general ICU at a university hospital in the south of Sweden, including 15 patients mechanically ventilated and sedated. Forty in-pair assessments using the Swedish version of the RASS were performed and the inter-rater reliability was tested using weighted kappa statistics (linear weighting).
The translation of the RASS was successful and the Swedish version was found to be satisfactory and applicable in the ICU. When tested for inter-rater reliability, the weighed kappa value was 0.86.
This study indicates that the Swedish version of the RASS is applicable with good inter-rater reliability, suggesting that the RASS can be useful for sedation assessment of patients mechanically ventilated in Swedish general ICUs.
近年来,对机械通气患者进行充分镇静的认识有所提高。使用镇静评分量表持续评估患者对镇静的反应可能会促进更早拔管,并可能对重症监护病房(ICU)的住院时间产生积极影响。里士满躁动镇静量表(RASS)提供了10个明确界定的等级,分为两个不同部分,包括镇静和躁动等级的标准。先前对RASS的研究表明它具有很强的信度和效度。本研究的目的是将RASS翻译成瑞典语,并在瑞典的一家ICU中测试该量表的评分者间信度。
将RASS从英语翻译成瑞典语,包括回译、严格审查和预试验。在瑞典南部一家大学医院的综合ICU中进行评分者间信度测试,包括15例接受机械通气并镇静的患者。使用瑞典版RASS进行了40次成对评估,并使用加权kappa统计量(线性加权)测试评分者间信度。
RASS的翻译很成功,发现瑞典版在ICU中令人满意且适用。在测试评分者间信度时,加权kappa值为0.86。
本研究表明,瑞典版RASS具有良好的评分者间信度,适用于瑞典综合ICU中机械通气患者的镇静评估。