OBJECTIVE: To evaluate the diagnostic performance of CareStart Malaria Pf/Pv Combo test relative to microscopy, for the diagnosis of falciparum and vivax malaria in Ethiopia. METHODS: Two hundred and forty febrile patients visiting the Serbo health center in Jimma zone, southwestern Ethiopia, were involved in this study in 2008. Giemsa-stained thin and thick blood smears were prepared and microscopically examined under a 100x oil immersion microscope objective for Plasmodium species identification and determination of parasitemia respectively. CareStart Malaria Pf/Pv Combo test was performed as per the manufacturers' instruction. FINDINGS: The validity of CareStart Malaria Pf/Pv Combo test for the diagnosis of Plasmodium was very good with a sensitivity of 95.8%, specificity of 100%, positive predictive value of 100% and negative predictive value of 96%. The test performed equally well for the identification of Plasmodium falciparum and P. vivax. The diagnostic performance of this CareStart test is comparable to light microscopy of thin and thick blood smears. CONCLUSION: Although CareStart Malaria Pf/Pv Combo test and blood microscopy have comparable diagnostic performance for Plasmodium detection, the CareStart test has the added advantage of being simple to interpret, cost-efficient, and hence it is preferable to use this rapid diagnostic test for malaria diagnosis in areas where microscopy is not accessible and during times of malaria epidemics that are observed approximately every 4-5 years in Ethiopia.
目的:评估 CareStart 疟疾 Pf/Pv 组合检测在诊断埃塞俄比亚间日疟原虫和恶性疟原虫感染方面相对于显微镜检查的诊断性能。
方法:2008 年,我们在埃塞俄比亚西南部 Jimma 地区的 Serbo 卫生中心招募了 240 名发热患者参与这项研究。制备吉氏染色薄血和厚血涂片,使用 100x 油浸显微镜物镜进行镜检,以分别确定疟原虫种类和寄生虫血症载量。按照制造商的说明进行 CareStart 疟疾 Pf/Pv 组合检测。
结果:CareStart 疟疾 Pf/Pv 组合检测用于诊断疟原虫的有效性非常好,其灵敏度为 95.8%,特异性为 100%,阳性预测值为 100%,阴性预测值为 96%。该检测对鉴定恶性疟原虫和间日疟原虫同样有效。该 CareStart 检测的诊断性能与薄血和厚血涂片的显微镜检查相当。
结论:虽然 CareStart 疟疾 Pf/Pv 组合检测和血液显微镜检查在疟原虫检测方面具有相当的诊断性能,但 CareStart 检测具有易于解释、成本效益高的优势,因此在显微镜检查不可用的地区,以及在埃塞俄比亚每 4-5 年发生一次的疟疾流行期间,使用这种快速诊断检测进行疟疾诊断更为可取。
Trop Med Int Health. 2011-7-12
Southeast Asian J Trop Med Public Health. 2005-5
Cochrane Database Syst Rev. 2020-11-4
Cochrane Database Syst Rev. 2020-11-4
Cochrane Database Syst Rev. 2014-12-18