Suppr超能文献

吸附技术在温自身免疫性溶血性贫血血清学评估中的应用。

Utility of adsorption techniques in serological evaluation of warm autoimmune haemolytic anaemia.

机构信息

Dept of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India.

出版信息

Blood Transfus. 2009 Oct;7(4):300-4. doi: 10.2450/2009.0079-08.

Abstract

BACKGROUND

Various adsorption techniques are available to remove serum autoantibodies and subsequently detect the underlying alloantibody in previously transfused patients with autoimmune haemolytic anaemia. We planned to establish a suitable adsorption technique in our transfusion service which can remove all autoantibodies and detect underlying alloantibodies rapidly, cheaply and effectively.

STUDY DESIGN AND METHODS

We evaluated 71 direct antiglobulin test-reactive patients with warm AIHA over a period of 20 months. Twenty-three of these 71 patients who had a previous history of blood transfusion or pregnancy and were confirmed carriers of autoantibodies (indirect antiglobulin test-reactive) were considered for the adsorption study. Depending on the adequacy of samples, history of blood transfusion and severity of anaemia either autoadsorption or alloadsorption or both using polyethylene glycol (PEG) or low ionic strength saline (LISS)-papain were performed.

RESULTS

Underlying alloantibodies were detected in 7 of the 23 patients (30.4%) and all these were specific to Rhesus antigens. The mean number of alloadsorptions for complete autoantibody removal using PEG was 1.43 which was significantly lower than the 3.9 using the LISS-papain method (p<0.05). The mean time required by PEG alloadsorption and LISS-papain alloadsorption for autoantibody removal was 93.6 minutes and 177.7 minutes, respectively (p<0.05). Discordant results were not observed in any case and identical alloantibodies were detected by both the techniques.

CONCLUSION

We found that the PEG method is a rapid, cheap and effective way to remove autoantibodies and detect underlying alloantibodies.

摘要

背景

有多种吸附技术可用于去除血清自身抗体,然后在先前因自身免疫性溶血性贫血接受过输血的患者中检测潜在的同种抗体。我们计划在我们的输血服务中建立一种合适的吸附技术,该技术可以快速、廉价且有效地去除所有自身抗体并检测潜在的同种抗体。

研究设计与方法

我们在 20 个月的时间里评估了 71 例直接抗球蛋白试验阳性的温抗体型自身免疫性溶血性贫血患者。这 71 例患者中有 23 例既往有输血或妊娠史,且被确认为自身抗体(间接抗球蛋白试验阳性)携带者,我们对这些患者进行了吸附研究。根据样本充足性、输血史和贫血严重程度,使用聚乙二醇(PEG)或低离子强度盐水(LISS)-木瓜蛋白酶进行自吸附或同种异体吸附或两者兼用。

结果

在 23 例患者中有 7 例(30.4%)检测到潜在的同种抗体,且所有这些抗体均特异性针对 Rh 抗原。使用 PEG 完全去除自身抗体所需的同种异体吸附平均次数为 1.43 次,明显低于使用 LISS-木瓜蛋白酶法的 3.9 次(p<0.05)。PEG 同种异体吸附和 LISS-木瓜蛋白酶同种异体吸附去除自身抗体所需的平均时间分别为 93.6 分钟和 177.7 分钟(p<0.05)。在任何情况下均未观察到不一致的结果,两种技术均检测到相同的同种抗体。

结论

我们发现 PEG 方法是一种快速、廉价且有效的去除自身抗体和检测潜在同种抗体的方法。

相似文献

引用本文的文献

8
Autoimmune hemolytic anemia: From lab to bedside.自身免疫性溶血性贫血:从实验室到床边
Asian J Transfus Sci. 2014 Jan;8(1):5-12. doi: 10.4103/0973-6247.126681.

本文引用的文献

1
Use of polyethylene glycol for performing autologous adsorptions.使用聚乙二醇进行自体吸附。
Transfusion. 2005 May;45(5):694-7. doi: 10.1111/j.1537-2995.2005.04369.x.
4
Autoimmune hemolytic anemia.自身免疫性溶血性贫血
Am J Hematol. 2002 Apr;69(4):258-71. doi: 10.1002/ajh.10062.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验