This study evaluated the efficacy of custom-made reverse geometry rigid gas permeable (RGP) contact lenses in the control of symptoms related to increased wavefront aberrations after LASIK correction of myopia.
Twenty-eight myopes treated with LASIK were assessed for post-LASIK symptoms (declined night vision, glare, halos and/or monocular diplopia) and corneal topography. A set of RGP contact lenses was selected as trial lenses based on the matching between the lens and the patient's corneal topography. If the fluorescein pattern between the trial lens and the corneal surface showed a central alignment, a mid-peripheral bearing and peripheral clearance and if the patient felt comfortable with the lens wear, a duplicated lens was ordered for the patient. Otherwise, a lens satisfied with corneal topography of the patient and clinical judgment was used. Visual acuity (VA) and wavefront aberrations were measured after the lens wear.
The custom-made lenses well matched the host cornea with no dislodgment in all subjects. The post-LASIK eyes showed an increase of 1 Snellen line in VA (from 0.90 +/- 0.33 to 1.11 +/- 0.24) and a significant improvement in all symptoms after the lens wear. The total higher-order aberration is significantly reduced after the lens wear with at least 70% reduction in either spherical aberration, coma, third or fourth aberration but only 33% reduction in the fifth aberration.
Reverse geometry RGP lenses with the design based on individual topographic data can improve visual performance of post-LASIK eyes by reducing higher order aberrations.
本研究评估了定制的反向几何硬性透气性隐形眼镜(RGP)对 LASIK 矫正近视后与增加的波前像差相关的症状的控制效果。
对 28 名接受 LASIK 治疗的近视患者进行了 LASIK 后症状(夜间视力下降、眩光、光环和/或单眼复视)和角膜地形图评估。根据镜片与患者角膜地形图的匹配情况,选择一组 RGP 隐形眼镜作为试镜。如果试镜与角膜表面之间的荧光素图案显示中央对齐、中周缘接触和周边间隙,并且患者对镜片佩戴感到舒适,则为患者订购一副复制镜片。否则,使用满足患者角膜地形图和临床判断的镜片。佩戴镜片后测量视力(VA)和波前像差。
定制镜片与所有受试者的宿主角膜匹配良好,无移位。LASIK 后眼的 VA 提高了 1 行(从 0.90 +/- 0.33 提高到 1.11 +/- 0.24),并且佩戴镜片后所有症状均显著改善。佩戴镜片后总高阶像差显著降低,球差、彗差、第三或第四像差至少降低 70%,但第五像差仅降低 33%。
基于个体地形图数据设计的反向几何 RGP 镜片可以通过降低高阶像差来改善 LASIK 后眼的视觉性能。