The effect of phacoemulsification cataract surgery on polarimetry and tomography measurements for glaucoma diagnosis.

机构信息

Applied Physics, Faculty of Science, University of Zaragoza, Zaragoza, Spain.

出版信息

J Glaucoma. 2010 Sep;19(7):468-74. doi: 10.1097/IJG.0b013e3181c4aed8.

Abstract

PURPOSE

To assess whether optical coherence tomography (OCT)Stratus 3000, confocal laser scanning ophthalmoscopy (HRT3), and scanning laser polarimetry (GDx-VCC) results show parameter differences between presurgery and postsurgery in patients with cataracts and suspected glaucoma.

SETTING

Glaucoma Service in the Department of Ophthalmology at the Miguel Servet University Hospital, Zaragoza, Spain.

METHODS

Forty-six eyes of 46 patients were enrolled in this cross-sectional study and examined with OCT, HRT3, and GDx-VCC before and after phacoemulsification. Differences between presurgery and postoperative measurements were calculated using nonparametric test.

RESULTS

The most significant difference between the study groups was in the OCT image quality; the signal-to-noise ratio improved from presurgery to postsurgery. All of the statistically significant sectors reflected measurements in the nasal region and the maximum superior and average nasal retinal nerve fiber layer (thickness (Smax/Navg). Almost all parameters of the HRT area remained unchanged after the surgery, but important differences were observed in cup depth, volume parameters, and image quality. The Glaucoma Progression Score feature may not be helpful in the presence of lens opacity. Temporal incision during the surgery affected most of the nasal GDx-VCC parameters and the image quality.

CONCLUSIONS

OCT image quality was reduced preoperatively in the eyes with cataracts and retinal nerve fiber layer thickness in the nasal sectors was increased in these eyes postoperatively. Cup depth, volume parameters, Glaucoma Progression Score, and the image quality of HRT measurements were all influenced by cataract removal. In our study temporal incision during surgery affected the nasal parameters in GDx-VCC. Our results suggest that the examiner should consider obtaining a new baseline measurement after cataract surgery.

摘要

目的

评估白内障合并疑似青光眼患者术前和术后应用光学相干断层扫描(OCT)Stratus 3000、共焦激光扫描检眼镜(HRT3)和扫描激光偏振仪(GDx-VCC)的结果是否存在参数差异。

背景

西班牙萨拉戈萨 Miguel Servet 大学医院眼科青光眼科。

方法

本横断面研究共纳入 46 例 46 只眼,所有患者均行白内障超声乳化术,术前和术后分别进行 OCT、HRT3 和 GDx-VCC 检查。采用非参数检验比较术前和术后的测量值。

结果

研究组间差异最显著的是 OCT 图像质量,术后信噪比提高。所有统计学上有显著差异的部位均反映了鼻侧区域和最大上侧及平均鼻侧视网膜神经纤维层(厚度(Smax/Navg)的测量值。HRT 面积的几乎所有参数在手术后均保持不变,但杯盘比、容积参数和图像质量有显著差异。在晶状体混浊存在的情况下,青光眼进展评分特征可能没有帮助。手术时颞侧切口影响了大多数 GDx-VCC 的鼻侧参数和图像质量。

结论

白内障患者术前 OCT 图像质量降低,术后鼻侧视网膜神经纤维层厚度增加。杯盘比、容积参数、青光眼进展评分和 HRT 测量的图像质量均受白内障切除的影响。在我们的研究中,手术时的颞侧切口影响了 GDx-VCC 的鼻侧参数。我们的研究结果提示,检查者应考虑在白内障手术后获得新的基线测量值。