Suppr超能文献

应用 Visante 光学相干断层扫描仪测量近视和散光可折叠型 Collamer 人工晶状体的眼内动态。

Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography.

机构信息

Department of Ophthalmology, University of Oslo, Norway.

出版信息

Ophthalmology. 2010 Jun;117(6):1245-50. doi: 10.1016/j.ophtha.2009.10.033. Epub 2010 Feb 16.

Abstract

PURPOSE

To study changes in vaulting of myopic and toric Implantable Collamer Lenses (ICLs) version 4 during accommodation with Visante optical coherence tomography (OCT), and analyze the relationship between vaulting and anterior subcapsular opacification.

DESIGN

Cross-sectional study.

PARTICIPANTS

Seventy-seven eyes of 77 myopic patients were examined after implantation with an ICL (48 myopic, 29 toric). The median follow-up time was 63 months (range, 10-84).

METHODS

The distance between the posterior ICL surface and the anterior surface of the crystalline lens was measured in the nonaccommodative state and during accommodation with Visante OCT. The lenses were examined for opacification using slit-lamp microscopy.

MAIN OUTCOME MEASURES

The distance between the ICL and the anterior surface of the crystalline lens.

RESULTS

At baseline, the mean distance between the ICL and the crystalline lens was 0.31+/-0.19 mm and during accommodation 0.31+/-0.26 mm; the difference did not reach significance (P = 0.77). The distance at baseline was significantly (P = 0.01) less in older patients and significantly (P = 0.04) greater in patients with a toric ICL. Contact was observed at baseline or during accommodation in 12 eyes; there was a significantly lower incidence of contact in eyes implanted with a toric ICL (P = 0.03). Anterior subcapsular opacification developed in 10 eyes, in 5 of these the ICL touched the crystalline lens.

CONCLUSIONS

Anterior subcapsular opacification developed in 13.0% of eyes. We found no difference in vaulting of the ICL at baseline and during accommodation. There was contact between the ICL and the crystalline lens in 15.6% of the eyes. The association between anterior subcapsular opacification and contact was significant (P = 0.004).

摘要

目的

使用 Visante 光相干断层扫描(OCT)研究近视和散光可植入 Collamer 透镜(ICL)版本 4 的拱高在调节过程中的变化,并分析拱高与前囊下混浊之间的关系。

设计

横断面研究。

参与者

77 名近视患者的 77 只眼接受 ICL 植入术后进行检查(48 只近视,29 只散光)。中位随访时间为 63 个月(范围 10-84 个月)。

方法

使用 Visante OCT 在非调节状态和调节状态下测量 ICL 后表面与晶状体前表面之间的距离。使用裂隙灯显微镜检查晶状体混浊情况。

主要观察指标

ICL 与晶状体前表面之间的距离。

结果

在基线时,ICL 与晶状体之间的平均距离为 0.31+/-0.19mm,在调节时为 0.31+/-0.26mm;差异无统计学意义(P = 0.77)。年龄较大的患者基线距离明显较小(P = 0.01),而散光 ICL 的患者距离明显较大(P = 0.04)。12 只眼在基线或调节时出现接触;植入散光 ICL 的眼接触发生率明显较低(P = 0.03)。10 只眼发生前囊下混浊,其中 5 只眼的 ICL 接触到晶状体。

结论

13.0%的眼发生前囊下混浊。我们在基线和调节时发现 ICL 的拱高没有差异。15.6%的眼的 ICL 与晶状体接触。前囊下混浊与接触之间存在显著相关性(P = 0.004)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验