Center for Pancreatic Disease, Division of Gastroenterology, Hepatology, and Endoscopy, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115, USA.
Pancreas. 2010 Aug;39(6):889-96. doi: 10.1097/MPA.0b013e3181cf16f4.
We aimed to establish the endoscopic pancreatic function test (ePFT) as a method that can safely obtain pancreatic fluid for mass spectrometric analysis from patients during upper endoscopy and to reproducibly identify pancreas-specific proteins.
We performed a sodium dodecyl sulfate-polyacrylamide gel electrophoresis and mass spectrometry-based proteomic analysis (in-gel tryptic digestion followed by liquid chromatography-tandem mass spectrometry [GeLC-MS/MS]) on ePFT-collected pancreatic fluid from 3 individuals, without evidence of chronic pancreatitis, who were undergoing an upper endoscopy for dyspepsia and chronic abdominal pain.
Pancreatic fluid was safely collected from all subjects. The sodium dodecyl sulfate-polyacrylamide gel electrophoretic analysis of ePFT-collected pancreatic fluid revealed no significant variation (F statistic, 1.33, P = 0.29) in protein concentration during the 1-hour collection period and a visually reproducible protein banding pattern among the 3 subjects. The GeLC-MS/MS analysis of ePFT-collected fluid identified pancreas-specific proteins previously described from endoscopic retrograde cholangiopancreatography and surgical collection methods. Gene ontology further revealed that most of the proteins identified have a molecular function of proteases.
The ePFT is capable of collecting large amounts of pancreatic fluid for proteomic analysis enabling the identification of pancreas-specific proteins. This endoscopic collection method coupled with GeLC-MS/MS is a powerful technique, which can be used in future investigations to elucidate pathways involved in the development and progression of pancreatic disease.
我们旨在建立内镜胰功能试验(ePFT),作为一种在上消化道内镜检查期间从无慢性胰腺炎证据的消化不良和慢性腹痛患者安全获取胰液进行质谱分析的方法,并可重现鉴定胰腺特异性蛋白。
我们对 3 名接受上消化道内镜检查的个体进行了基于十二烷基硫酸钠-聚丙烯酰胺凝胶电泳和质谱分析(胶内胰蛋白酶消化后进行液相色谱-串联质谱 [GeLC-MS/MS])的胰液蛋白质组学分析。
所有受试者均安全采集胰液。ePFT 采集的胰液的十二烷基硫酸钠-聚丙烯酰胺凝胶电泳分析显示,在 1 小时的采集期间,蛋白质浓度没有明显变化(F 统计,1.33,P = 0.29),并且 3 名受试者之间的蛋白带型具有视觉重现性。ePFT 采集的液体的 GeLC-MS/MS 分析鉴定出了先前从内镜逆行胰胆管造影术和外科采集方法描述的胰腺特异性蛋白。基因本体论进一步表明,所鉴定的大多数蛋白质具有蛋白酶的分子功能。
ePFT 能够收集大量的胰液进行蛋白质组学分析,从而鉴定胰腺特异性蛋白。这种内镜采集方法与 GeLC-MS/MS 相结合是一种强大的技术,可用于未来的研究,以阐明参与胰腺疾病发展和进展的途径。