Suppr超能文献

幼儿腓肠肌内侧头肌肉结构超声量化的变异性与可靠性

Variation and reliability of ultrasonographic quantification of the architecture of the medial gastrocnemius muscle in young children.

作者信息

Legerlotz Kirsten, Smith Heather K, Hing Wayne A

机构信息

Department of Sport and Exercise Science, University of Auckland, Auckland, New Zealand.

出版信息

Clin Physiol Funct Imaging. 2010 May;30(3):198-205. doi: 10.1111/j.1475-097X.2010.00925.x. Epub 2010 Feb 23.

Abstract

The aim of this study was to evaluate the suitability of ultrasonography for the quantification of gastrocnemius muscle architecture in healthy young children. The variation and reliability of measurement of muscle thickness, pennation angle and fibre length of the medial gastrocnemius were determined, using stationary and portable ultrasound machines, in 13 boys and eight girls aged 4-10. Ultrasound images were obtained from each leg, in duplicate, with the ankle at 90 degrees , then at maximal plantar flexion, with the two machines within the same session. The same set of 16 scans was repeated in four children 4-6 weeks later. The mean muscle thickness, pennation angle and fibre length differed between ankle positions and between legs. Measurements obtained using the two machines established similar values with no significant differences in absolute values and coefficients of variation (CV). For duplicate images taken during the same session for the same leg, ankle position and machine, the CV and intraclass correlation coefficients (ICC) ranged, respectively, from 2.1% to 3.1% and 0.94-0.98 for muscle thickness, from 4.1% to 6.0% and 0.85-0.96 for pennation angle and from 4.5% to 6.3% and 0.87-0.96 for fibre length. Corresponding values for variables for the same child measured on two separate occasions were within the same ranges, all being similar to reliability data reported previously for adult muscle. Muscle thickness, pennation angle and fibre length of the medial gastrocnemius can therefore be quantified reliably, using either a stationary or portable ultrasound machine, in healthy young children.

摘要

本研究的目的是评估超声检查对健康幼儿腓肠肌肌肉结构定量分析的适用性。使用固定式和便携式超声仪,对13名4至10岁男孩和8名女孩的腓肠肌内侧肌肉厚度、羽状角和纤维长度测量的变异性及可靠性进行了测定。在踝关节呈90度以及最大跖屈时,从每条腿获取超声图像,一式两份,两台仪器在同一次检查中使用。4至6周后,对4名儿童重复进行相同的16次扫描。踝关节位置和双腿之间的平均肌肉厚度、羽状角和纤维长度存在差异。使用两台仪器获得的测量值相近,绝对值和变异系数(CV)无显著差异。对于同一条腿、踝关节位置和仪器在同一次检查中拍摄的重复图像,肌肉厚度的CV和组内相关系数(ICC)分别为2.1%至3.1%和0.94 - 0.98,羽状角为4.1%至6.0%和0.85 - 0.96,纤维长度为4.5%至6.3%和0.87 - 0.96。在两个不同时间对同一儿童测量的变量对应值在相同范围内,均与先前报道的成人肌肉可靠性数据相似。因此,使用固定式或便携式超声仪均可在健康幼儿中可靠地定量腓肠肌内侧的肌肉厚度、羽状角和纤维长度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验