Suppr超能文献

2008 年在乌干达北部使用滴滴涕进行室内滞留喷洒 6 个月后疟疾控制人员的滴滴涕/滴滴伊的血浆水平和肝功能。

Plasma levels of DDT/DDE and liver function in malaria control personnel 6 months after indoor residual spraying with DDT in northern Uganda, 2008.

机构信息

Pathology Department, School of Biomedical Sciences, College of Health Sciences, Makerere University, Kampala, Uganda.

出版信息

S Afr Med J. 2010 Jan 29;100(2):118-21. doi: 10.7196/samj.3321.

Abstract

OBJECTIVE

We investigated the relationship between plasma levels of dichlorodiphenyltrichloroethane (DDT) and liver function in malaria control personnel 6 months after one round of DDT indoor residual spraying (IRS).

METHOD

This was a cross-sectional study in the districts of Apac and Oyam of Lango, northern Uganda. Volunteers were clinically examined, and 5 ml samples of venous blood were taken in heparinised tubes for a 6-month post-spray screening for DDT and plasma markers of liver function and internal organ disease. DDE/DDT was assayed using ELISA kits (Abraxis, USA); plasma enzyme activity concentrations of amylase, aspartate aminotransferase (AST), alanine aminotransferase (ALT) and gamma glutamyl transpeptidase (GGT) were analysed using routine clinical chemistry-automated methods (Konelab, Vantaa, Finland).

RESULTS

All 96 plasma samples analysed for xenobiotics contained DDE/DDT in the empirical range of 24.00 - 128.00 parts per billion (ppb) with a mean (SD) of 77.00 (+/-26.00) ppb. All 119 plasma samples studied for the markers exhibited enzyme activity concentration values within the population reference ranges, with empirical means (SD) of amylase 71.86 (34.07), AST 23.83 (12.71), ALT 7.84 (10.01) and GGT 58.37 (62.68) microg/l.

CONCLUSION

Six months after IRS with DDT, the spray team had an average concentration of plasma DDE/DDT of 77 ppb. This had no deleterious effect on liver function. We recommend continued use of DDT for IRS disease control in Uganda until better practical alternatives are available.

摘要

目的

在马拉维北部兰戈地区的阿帕克和奥亚马区,我们调查了一轮滴滴涕室内滞留喷洒(IRS)后 6 个月控制疟疾人员血浆中滴滴涕(DDT)水平与肝功能之间的关系。

方法

这是一项在阿帕克和奥亚马区的横断面研究。志愿者接受临床检查,并采集 5ml 肝素化静脉血样本,用于在喷洒后 6 个月进行 DDT 筛查和血浆肝功能及内脏器官疾病标志物检测。使用 ELISA 试剂盒(美国 Abraxis)测定 DDE/DDT;采用常规临床化学自动分析方法(芬兰 Konelab)分析血浆酶活性浓度,包括淀粉酶、天门冬氨酸氨基转移酶(AST)、丙氨酸氨基转移酶(ALT)和γ-谷氨酰转肽酶(GGT)。

结果

所有 96 份分析的外来化学物质的血浆样本均含有经验范围内的 DDE/DDT(24.00-128.00 皮克/分升),平均(标准差)为 77.00(+/-26.00)ppb。所有 119 份用于标志物研究的血浆样本的酶活性浓度值均在人群参考范围内,经验平均值(标准差)分别为淀粉酶 71.86(34.07)、AST 23.83(12.71)、ALT 7.84(10.01)和 GGT 58.37(62.68)μg/L。

结论

在滴滴涕 IRS 后 6 个月,喷洒队的血浆 DDE/DDT 平均浓度为 77ppb。这对肝功能没有不良影响。我们建议继续在乌干达使用滴滴涕进行 IRS 疾病控制,直到有更好的实际替代方案。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验