Suppr超能文献

磁共振灌注成像无需造影剂。

Magnetic resonance perfusion imaging without contrast media.

机构信息

University Hospital of Tübingen, Germany.

出版信息

Eur J Nucl Med Mol Imaging. 2010 Aug;37 Suppl 1:S52-64. doi: 10.1007/s00259-010-1456-7.

Abstract

PURPOSE

Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue.

METHODS

After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue.

RESULTS

ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time.

CONCLUSIONS

Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs.

摘要

目的

本文系统地报告和分析了不使用造影剂而提供与灌注相关的对比权重的磁共振成像技术原理。特别详细描述了允许定量评估特定灌注率的动脉自旋标记(ASL)灌注成像的常见方法。ASL 技术在多种类型的组织中进行了灌注成像的潜力测试。

方法

在对连续和脉冲 ASL 技术的技术方面进行系统比较后,报告了标准动力学模型和对灌注定量测量有影响的组织特性。对于本文中演示的应用,开发并在全身扫描仪上实现了一种流动敏感交替反转恢复(FAIR)ASL 灌注准备方法,随后进行真正快速成像与稳态进动(true FISP)数据记录,用于在各种类型的组织中进行定量灌注测量。

结果

ASL 成像提供了一种非侵入性的工具,可用于评估体内组织的灌注率。从肾脏、肺、脑、唾液腺和甲状腺记录的图像在 2-5 分钟的检查时间后提供了毫米级的空间分辨率和足够的灌注图信号噪声比。

结论

新开发的 ASL 技术在灌注率相对较高(如许多肿瘤中也存在)的组织中提供了特别高的图像质量和定量灌注图。采集的平均和图像减影程序是必需的,这导致必须将数据记录与腹部和胸部器官的呼吸同步。

文献AI研究员